Convotherm OEB Series Service Handbook page 197

Table of Contents

Advertisement

Service Handbook OGS/OGB
 Attention: Hang the measuring unit on the "right" chimney!
OGS
6.10
6.20
10.10
10.20
12.20
OGS
20.10
*
20.20
*
 Measure the gas exhaust value, after 1 minute read the measured value and
check with the CO
 Record the CO
and check the cause of the excessive CO value.
If necessary, set the correct value (see chart 4) by adjusting the Venturi screw
(1) with the screw driver.
 Attention: Read the measured value at least 1 minute after adjustment!
AS/11-2011 / Part No.: 7016396
HL2
HL1
value on the Chart 4 "Gas exhaust values @ Max".
2
and CO values. At a CO value > 500 ppm switch off the unit
2
O
2
CO
2
OGB
6.10
6.20
10.10
10.20
12.20
OGB
20.10
*
20.20
*
Chart 4: Gas exhaust values @ Max
All gas types O
All gas types
Erdgas /
Natural Gas
CO
LP Gas =
Propan
Butan
O
2
CO
2
6_25e_Readjusting the Gas valves_d
.= 4,8%±0,3%
2
 = 1,30±0,02
= 9,0%±0,1%
2
CO
=
2
10,5%±0,2%
CO
=
2
12,2%±0,3%
Page 7 / 12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents