Convotherm OEB Series Service Handbook page 259

Table of Contents

Advertisement

Service manual OEB/OES/OGB/OGS
OEB OES OGB OGS Defect
5.2
General
KD / 19.08.2009
5.2.1 No interior lighting, however
appliance fully functioning
5.2.2 After starting a programme
appliance not functioning
5.2.3 Not enough water,
however no display of the
insufficient water symbol in the
display of the electronics, boiling
dry of the immersion heaters
5.2.4 Water runs underneath the
floor of the appliance from the
condenser overflow
5.2.5 Water inside the oven
5.2.6 No temperature increase
in convection mode
5.2.7 Uneven browning
Possible cause or remedy
Light bulb of interior light defective
Microfuse defective
Doors not closed
Magnet on the door is not in the right
position
Solenoid switch in the door stud defective
Check setup of the appliance (examine floor
model for warping)
Appliance is set to dummy version
normal version: c12=305; c13=999 (at
easyToUCH units see chapter 6.6)
Due to insufficient rinsing of the steam
generator foaming water
Water level sensor has short circuit to earth
due to contamination/calcium in the steam
generator
Contact problem on level sensor (possibly
short circuit to earth)
Opening in the area in the steam generator
touching the water closed by calcium
deposits
Building's drainage pipe blocked
Building's tundish funnel blocked
Dirt filter in the outflow of the working
chamber contaminated
Condenser blocked (dirt filter not present)
Demoisturisation tray dirty
Safety temperature limiter B7 has tripped
Heater contactors do not pull in
a) Contact problem on heater terminals
b) Heater contactor defective
Hot air heaters defective
Suction plate not correctly fitted
Heat produced by the hot air heater is too
low
Application error: e. g. not sufficiently pre-
heated
Load not centrally placed in the oven
5_00e_Troubleshooting list and error messages - Electronics_h.doc