Alarms/Messages/Alarm Log - Siemens SINUMERIK 840D Operator's Manual

Hmi advanced
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

8
"Diagnosis" Operating Area

8.2 Alarms/messages/alarm log

8.2
Alarms/messages/alarm log
Alarms
Reset
Cycle Start
Messages
Alarm
log
Display
new
Save log
Sorting
old -> new
8-406
Function
You can display a list of alarms and messages and acknowledge
them.
Operating sequence
Alarms:
The alarm overview displays all active alarms with alarm numbers,
date, clearance criteria and descriptions.
Clear the alarm by pressing the key that is displayed as a symbol:
Switch device off and on again (main switch)
or NCK POWER ON
Press "Reset" key.
Press "Alarm Cancel" key.
Alarm is cleared by "NC Start".
Alarm is cleared with the "Recall" key.
Messages:
PLC operational messages that do not have to be acknowledged (as
standard) (configurable).
Alarm log:
A log containing the alarms and messages that have so far occurred
is displayed. 150 alarms/messages can be logged as standard.
It also contains the alarms that have already been acknowledged.
This symbol means "Alarm is still active".
The alarm is updated (static display).
By pressing this softkey, the current status of the log is stored in the
displayed path and can be archived from here as required.
Changing the chronological sorting sequence of the alarms in the
display.
SINUMERIK 840D/840Di/810D Operator's Guide HMI Advanced (BAD) – 03.04 Edition