3 Function descriptions
3.1 WaveClean
Overview of functions
Description 1. Testing the cooking chamber temperature.
a
b
a Solenoid valve K12
b Pump G16
The following purification stages are available on the fully automatic
cleaning WaveClean:
•
Short: duration of about one hour
•
Normal: duration about two hours
•
Extra: duration approximately three hours
Automatic cooling of the cooking chamber, if > 55°C.
2. Inserting the WaveClean cartridge.
3. Water exchange of siphon content by the siphon pump G24 and
solenoid valve K12.
4. Circulation of water by means of pump G16. Thus pre-cleaning of
the cooking chamber. Then anew siphon water exchange.
The heater heats the oven to 55°C.
Service instructions
Function descriptions
c
c Pump G24
9