Main Index > Unit > Auxiliary
Parameter
Function
TSP Output
Time Scheduler Output; Jumpline to settings Off
Analog output
Actual Value analog Output according to
active Fan Stage
A outp fan step 0
Output Value if Fan is Off (Default)
A outp fan step 1
Output Value if Fan Stage 1 (setpoint stage
1) active
A outp fan step 2
Output Value if Fan Stage 2 (setpoint stage
2) active
A outp fan step 3
Output Value if Fan Stage 3 (setpoint stage
3) active
Alarm input
Alarm Input only for Alarming
Input
Digital Input only for display
Auxiliary tmp
Temperature ony for display
Op mode output
Output if the selected Operation Mode is
active
Op mode outp select Operation Mode Selector (set the condition
when the Output is active according to the
acual state of the Unit)
Main Index > Unit > Auxiliary > TSP output
Parameter
Function
Output
Time Scheduler Output
Manual operation
Operation over HMI
NULL = no acces over HMI, TSP or BMS
could be active
Off and On = override from HMI
Schedule
Jumpline to the Scheduler
Calendar exception
Jumpline to the Calendar
From BACS
Selection from where the Output is activated
Auto = TSP
Off and On = override from BMS
Main Index > Unit > Loop controllers
Parameter
Function
Supply fan
Actual Value; Jumpline to Controller settings 0...100
Exhaust fan
Actual Value; Jumpline to Controller settings 0...100
Air quality
Actual Value; Jumpline to Controller settings 0...100
Casc controller tmp
Actual Value Heating/ Cooling; Jumpline to
Controller settings
Min supply tmp
Actual Value; Jumpline to Controller settings 0...100
Siemens
Building Technologies

17.18 Auxiliary

17.18.1 General
17.18.2 TSP output

17.19 Loop controllers

Basis Document Siemens Climatix Control System
Standard application AHU
BDCX.100820.01GB
HMI
Value range
Unit
On
0...100
%
0...100
%
0...100
%
0...100
%
0...100
%
Passive
Active
Off
On
-64...64
°C
Off
On
Off
On/comfort
Economy.
Manual
Osstp
Night clg
UnOcc
Night kick
Fire dmper
Fire
Stop.
Heat
Hrec
Value range
Unit
Off
On
Off
On
NULL
Off
On
Passive
Active
Auto
Off
On
Value range
Unit
%
%
%
0...100
%
%
Standard
R S Link
Off
6
0
6
0
4
0
4
100
4
100
4
X
Chapter:
5.13.1
X
X
x
Off
4
Standard
R S Link
Off
X
NULL
X
Chapter:
On
4
5.13.2
4
Auto
Standard
R S Link
X
X
X
X
X
209 / 244