Configuration I/Os - Siemens Climatix Series Basis Document

Hide thumbs Also See for Climatix Series:
Table of Contents

Advertisement

Main Index > Configuration > Configuration 2
Parameter
Function
Aux tmp sensor
Auxiliary Temperature sensor
Aux TSP output
Auxiliary Output with own Scheduler
Aux A outp fan
Auxiliary analog Output which is setted
according to the actual Fan Step the
Aux op mode indicat
Auxiliary Output which Indicate the selected
Operation Mode
Configuration 2
If Configuration 2 is done this must be setted
to done
Reset required !!
After Configuration 2 done a reset is needed
for take away not needed Lines from
Configuration 2
Main Index > Configuration > Configuration IO's
Parameter
Function
Temperatures
Jumpline to Configuration IO's
Temperatures
Pressures/Flows
Jumpline to Configuration IO's
Pressures/Flows
Humidity
Jumpline to Configuration IO's Humidity
Digital inputs
Jumpline to Configuration IO's digital Inputs
Digital alarms
Jumpline to Configuration IO's digital
alarms
Other
Jumpline to Configuration IO's Air Quality,
External setpoint
Outputs damper
Jumpline to Configuration IO's Supply-,
Exhaust-, Firedampers
Outputs fans
Jumpline to Configuration IO's Exhaust-,
Supply Fan
Outputs tmp control
Jumpline to Configuration IO's for all
Temperatur sequence relatet Elements like
Heating, Cooling
Outputs humidifier
Jumpline to Configuration IO's digital
alarms
Outputs auxiliary
Jumpline to Configuration IO's digital
alarms
Outputs alarm
Jumpline to Configuration IO's digital
alarms
Configuration IO's
If Configuration IO's is done this must be
setted to done for internal lockings
Reset required !!
After Configuration IO's is setted to done, a
reset is needed before starting the
parametrising from the Airhandling Unit
Main Index > Configuration > Configuration IO's >Temperatures
Parameter
Function
HW IO:
Supply air
Supply air temperature
Room
Room temperature 1
Room 2
Room temperature 2
Exhaust air
Exhaust air temperature
Outside air
Outside air temperature
Heating frost
Heating frost protection temperature
Heat recovery water
Heat recovery water temperaure
Extract air
Extract air temperature
Hrec supply air
Heat recovery supply temperature
Supply air 2
Supply air 2 temperature (needed if Htg 2
and/or Clg 2 have own Sequence
Heating 2 frost
Heating 2 frost temperature
Auxiliary
Auxiliary temperature
184 / 244
Basis Document Siemens Climatix Control System
Siemens
Page 184
BDCX.100820.01GB
Building Technologies
17.8

Configuration I/Os

17.8.1 Temperatures
Standard application AHU
HMI
Value range
Unit
No
Yes
No
Yes
No
Yes
No
Yes
Done
NotDone
Passive
Active
Value range
Unit
Done
NotDone
Passive
Active
Terminal
Type
Pos:
Type:
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
NUsd,Comm,X1...X28 Pt1k...NTC10k
Standard
R
S Link
No
4
No
4
No
4
No
4
Section:
15.2
NotDone
4
Passive
4
Standard
R
S Link
4
4
4
4
4
4
Section:
NotDone
4
Passive
4
R
S Link
4
4
4
4
4
Section:
4
4
4
4
4
4
4
CE1P3977en_02