Main Index > Unit > Humidity control > Humidification
Parameter
Function
Controller
Actual Value Controller; Jumpline to settings 0...100
Output signal
Actual Output Signal; Jumpline to settings
Command
Humifiier status; Jumpline to settings
Feedback
Humidifier Feedback; Jumpline to settings
Pump.
Pump Status; jumpline to Pump settings
Start up delay fdbk
After this Time the Feedback has to be
TRUE
Off by fdbk alarm
In case of a Feedback Alarm the Pump is
switched Off
Main Index > Unit > Humidity control > Humidification > Pump
Parameter
Function
Command
Pump command
Feedback
Pump Feedback
Alarm
Pump Alarm
Start up delay fdbk
After this Time the Feedback has to be
TRUE
Off by fdbk alarm
In case of a Feedback Alarm the Pump is
switched Off
Min run time
Mnimum On Time after a Start
Kick date / time
Pump Kick Date and Time
Kick interval
Intervall Time for Pump Kick
Kick on time
Pulse length for Pump Kick
Main Index > Unit > Humidity control > Humidification > HumFancomp
Parameter
Function
Controller
Actual Value Controller; Jumpline to settings 0...100
Setpoint
Setpoint for the controller (related to the
actual Room Humidity)
Function
Defines if the speed of the Fans increases
or decreases if Setpoint is < than Humidity
Main Index > Unit > Air quality control
Parameter
Function
Controller
Actual Value; Jumpline to Controller settings 0...100%
Function
Direction of the Output (0..100 or 100..0)
Setpoint
Setpoint for the controller
208 / 244
Basis Document Siemens Climatix Control System
Siemens
Page 208
BDCX.100820.01GB
Building Technologies
17.16.5 Humidification
17.16.6 Humidification > Pump
17.16.7 Humidification > Fan compensation

17.17 Air qualtity control

Standard application AHU
HMI
Value range
Unit
%
0...100
%
On
Off
No Fdb
Ok
Off
On
0...36000
--- S ---
No
Yes
Value range
Unit
On
Off
NoFdbk
Fdbk
Ok
Alarm
0...36000
--- S ---
No
Yes
0...36000
--- S ---
0.0...36000.0
h
0...36000
--- S ---
Value range
Unit
%
0...100
%
Increase
Decrease
Value range
Unit
Normal
Inverted
0...3000
ppm
Standard
R S Link
X
X
X
X
Section:
4
5.11.5
10
6
Yes
6
Standard
R S Link
X
X
X
Section:
5.11.6
6
Yes
6
180
6
6
Section:
168.0
6
5.11.7
60
6
Standard
R S Link
X
50.0
6
Section:
5.11.8
Increase
6
Standard
R S Link
X
Normal
4
Section:
5.12
800
4
CE1P3977en_02
01.02.2010