Auxiliary Function Transfer From Nc Channel - Siemens SINUMERIK 808D ADVANCED Parameter Manual

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

corresponding to ...
Note for the reader
5.4

Auxiliary function transfer from NC channel

DB2500
DBX4.0 to .4
DBX6.0
DBX8.0
DBX10.0
DBX12.0 to .2
Edge evaluation: No
Signal state 1
Signal state 0
Note for the reader
DB2500
DBB1000 to DBB1012
Edge evaluation: No
Signal state 1
Signal state 0
Application
corresponding to ...
Note for the reader
DB2500
DBD2000
Edge evaluation: No
Signal state 1
Signal state 0
Application
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
5.4 Auxiliary function transfer from NC channel
DB1900 DBX0.7 (switchover Machine/Work)
Operating manual (corresponding to the software being used)
M function Change 1 to 5
S function Change 1
T function Change 1
D function Change 1
H function Change 1 to 3
Signal(s) from channel (PLC)
Signal(s) updated: Cyclic
M, S, T, D, H information was output at the interface together with a new value
and the associated change signal. In this case, the change signal indicates
that the corresponding value is valid.
The change signals are only valid for one PLC cycle! This means that if the
signal is 1, then a change is pending for this cycle.
The value of the data involved is not valid.
Function Manual Basic Functions H2
Decoded M signals: M0 - M99
Signal(s) from channel (NCK)
Signal(s) updated: Cyclic
The dynamic M signal bits are set by decoded M functions.
For a general auxiliary function output, the dynamic M signal bits are ac‐
knowledged by the PLC system program after the user program has been
completely run-through (executed once).
Spindle clockwise/counterclockwise rotation, switch coolant on/off
IS "M function for the spindle (DINT), axis-specific" (DB370x DBD0)
Function Manual Basic Functions H2
T function 1
Signal(s) from channel (PLC)
Signal(s) updated: job-control‐
led by NCK
The T function programmed in an NC block is made available here as soon
as the T change signal is available.
Value range of the T function: 0-32000 ; integer number
The T function remains valid until it is overwritten by a new T function.
● After the PLC has ramped-up.
● All auxiliary functions are deleted before a new function is entered.
Control of automatic tool selection.
Detailed descriptions of interface signals
365