17.16 Humidity Control - Siemens Climatix Series Basis Document

Hide thumbs Also See for Climatix Series:
Table of Contents

Advertisement

Main Index > Unit > Temp control > Cooling 2 > Clg 2 max limit fan
Parameter
Function
Fan stage 0
Only visible if plant is not configured, not
used! Fix setted to 0
Fan stage 1
Max Output Value for Stage 1
Fan stage 2
Max Output Value for Stage 2
Fan stage 3
Max Output Value for Stage 3
Main Index > Unit > Temp control > Fan heating
Parameter
Function
Controller
Actual Value Controller; Jumpline to settings 0...100
Deadzone
Heating Deadzone for Fan compensation
Main Index > Unit > Temp control > Fan cooling
Parameter
Function
Controller
Actual Value Controller; Jumpline to settings 0...100
Deadzone
Cooling Deadzone for Fan compensation
Main Index > Unit > Temp control > Fan comp tmp
Parameter
Function
Controller
Actual Value Controller; Jumpline to settings 0...100
Setpoint
Setpoint for the controller (related to the
actual Room or Exhaust Temperature)
Function
Defines If the speed of the Fans increases
or decreases if Setpoint is < than
Temperaure
Main Index > Unit > Humidity control
Parameter
Function
Act controlled hum
Actual Value of the controlled humidity
Setpoints
Jumpline to Humidity Setpoints
Cascade controller
Jumpline to settings for Cascade Controller
Actual Value humidification
Actual Value dehumidification
Max controller sply
Jumpline to settings for Max humidification
controlling
Humidification
Actual Value; Jumpline for Hunidification
settings
Dehumidification
Actual Value; Jumpline to Dehumidification
controlller
Fan compensation
Actual Value; Jumpline for Fan
Compensation settings
Summer disable
Block the Humidification in Summer
Dew point
Calculated Dewpoint
Dewpoint deadzone
Dew point Deadzone for contorlling
206 / 244
Basis Document Siemens Climatix Control System
Siemens
Page 206
BDCX.100820.01GB
Building Technologies
17.15.32
Cooling 2 > Max limitation fan
17.15.33
Fan heating
17.15.34
Fan cooling
17.15.35
Fan compensation

17.16 Humidity control

17.16.1 General
Standard application AHU
HMI
Value range
Unit
0...100
%
0...100
%
0...100
%
0...100
%
Value range
Unit
%
0...20
°C
Value range
Unit
%
0...20
°C
Value range
Unit
%
0...99
°C
Increase
Decrease
Value range
Unit
%rH, g/kg
%rH, g/kg
0...100
%
0...100
%
0...100
%
No
Yes
-64...64
°C
-64...64
°C
Standard
R S Link
0
6
100
6
Section:
100
6
0
100
6
Standard
R S Link
X
Section:
1.0
6
5.5.6
Standard
R S Link
X
Section:
1.0
6
5.5.6
Standard
R S Link
X
20.0
6
Section:
5.5.7
Increase
6
Standard
R S Link
X
X
X
X
X
Section:
5.11.1
X
X
No
6
X
6
CE1P3977en_02