IBM 3592 Maintenance Information page 96

Rack mount models
Hide thumbs Also See for 3592:
Table of Contents

Advertisement

X'02
TRANSPORT FAULT - Failure in the transport layer.
X'03
COMMAND TIMEOUT - Command that is timed out before completion. AIX device driver (Atape).
The example shows a failure.
X'04
NO DEVICE RESPONSE - Target did not respond to attempts to select it.
X'05
ADAPTER HARDWARE FAILURE - Adapter indicated a hardware failure.
X'06
ADAPTER SOFTWARE FAILURE - Adapter indicated a microcode failure.
X'07
WW NAME CHANGE - Adapter detected a new worldwide name for the device.
X'08
FUSE OR TERMINAL PWR - Blown terminator fuse or bad termination.
X'09
TRANSPORT RESET - Adapter detected an external SCSI bus reset.
X'0A
TRANSPORT BUSY - The transport layer is busy.
X'0B
TRANSPORT DEAD - The transport layer is inoperative.
ss...
X'00...
DEVICE SENSE DATA - Since the first byte is not '70,' '71,' 'F0,' or 'F1,' the area that is normally
reserved for device sense data is not valid (and therefore contains zeros). If byte 'gg' indicates a
check condition, the 'ss' byte contains '70,' '71,' 'F0,' or 'F1'. The remaining bytes are valid device
sense data. See the appropriate device reference manual for the specific format and content of
these bytes.
76 IBM 3592 TS1140, TS1150, TS1155, and TS1160 Tape Drives: Maintenance Information