Table 6: Supported TapeAlert flags. The No. column is presented in decimal format, not hexadecimal format.
(continued)
No.
Flag
Description
51
Tape
The tape directory on the tape
directory
cartridge that just unloaded is
invalid at
corrupted. File search
unload
performance is degraded.
52
Tape system
The unloaded tape cannot write
area write
its volume control region (VCR)
failure
successfully.
53
Tape system
The tape VCR cannot be read
area read
successfully at load time.
failure
54
No start of
The start of data cannot be found
data
on the tape.
55
Load failure
The operation failed because the
media cannot be loaded and
threaded.
56
Unload
Tape does not eject and might
failure
require manual removal.
57
Interface
This flag is set when the tape
drive detects a problem with the
RS-422 (LDI) interface. It is
cleared when the drive is
powered OFF, or a successful
microcode update is completed.
58
Firmware
Microcode problem
failure
59
WORM
Drive determined that data on
medium -
tape is suspect, from a WORM-
integrity
point of view.
check failed
60
WORM
This flag is set when the drive
medium -
rejects a write operation because
overwrite
the rules for allowing WORM-
attempted
writes are not met. Data can be
appended only to WORM media.
Overwrites to WORM media are
not allowed.
Customer action
CE action
Customer action
Can be caused by power failure
optional. The drive
or reset while tape is reading/
automatically
writing. If problem persists, go
rebuilds the
to "FID 87 or F2 - Isolating fault
directory as data is
between media and hardware"
read or the operator
on page 243.
can reread all data
from the tape to
rebuild the
directory.
Try another tape.
Go to "FID 87 or F2 - Isolating
fault between media and
hardware" on page 243.
Try another tape.
Go to "FID 87 or F2 - Isolating
fault between media and
hardware" on page 243.
Verify that you are
Go to "FID 87 or F2 - Isolating
using the correct
fault between media and
format tape. Try
hardware" on page 243.
another tape.
Remove tape; try
Remove the cartridge. If
another tape.
problem persists, see 'Load
Error" in Table 5 on page 11.
Go to "Manual cartridge
1. Press Unload.
removal" on page 195.
2. Call for Service.
Call for Service.
See Note 1.
Call for Service
Go to "FID 83 or E5 - Microcode
problem" on page 239.
None
1. Copy the data to
another WORM
tape cartridge.
2. Discard the faulty
WORM tape
cartridge.
Write the data to a
None
WORM tape
cartridge or write
the data to a non-
WORM tape
cartridge.
Start 17