Table 16: LED indicators for EH7/EH8/55F/60F (continued)
2
Drive status
3
Ethernet
communi-
1
cation
4
Information
5
Port 0 - Fibre
Channel
activity
6
Port 1 - Fibre
Channel
activity
Notes:
1. The Ethernet Communication LED is always off unless the CE or the customer is connected to the
Ethernet port at the front of the enclosure.
2. The Information LED is not lit. However, even if it is, it is not a cause to replace the drive. If it is on,
the fan is probably running at full speed.
Power supplies
32 IBM 3592 TS1140, TS1150, TS1155, and TS1160 Tape Drives: Maintenance Information
Yellow
• Cartridge status not
indicated
• No message or error
• POR diagnostic in
progress
Green
• Cartridge present
• No message or error
• POR diagnostic
completed
Yellow
N/A
Green
N/A
2
Blue
N/A
Yellow
N/A
Green
Fibre Channel
connections are
detecting light, but no
data is being
transferred. Wrap
tools are installed or
drive canister is offline
to host.
Yellow
N/A
Green
Fibre Channel
connections are
detecting light, but no
data is being
transferred. Wrap
tools are installed or
drive canister is offline
to host.
• Cartridge not
• Cartridge not
present
• Message or error
• No message or error
• POR diagnostic
• POR diagnostic
completed
• Cartridge present
• Message or error
• POR diagnostic
completed
N/A
No communications
since last POST of
Ethernet
drive
communication
activity
N/A
N/A
Fibre Channel
• No light is detected
connections are good;
not ready to transmit
Fibre Channel
• Fibre Channel cable
connections are good;
data is being
• Port is not in use
transferred
• Fibre wrap plug is
• Drive was not
Fibre Channel
connections are good;
not ready to transmit
Fibre Channel
connections are good;
data is being
transferred
present
completed
through Fibre
Channels
is disconnected
installed on the port
returned to operator
mode (is still in CE
offline mode or CE
online mode)