SUMMARY
OF SYSTEM
FEATURES
General
Information
NOTE: At least one
5137AD
or 6139
addressable
alpha
display console must
be used with this
system.
The following table lists the major features of the 4140XMPT2 system.
~ystem
The 4140XMPT2 Control is a microprocessor based,
programmable, partitioned system, and features EEROM
memoty technology (power bss does not result in the
bss of information).
?ones Supported
Suppotts up to 9 traditional wired zones of protection.
Q Expandable to 87 zones (consisting of combinations of
wired and/or wireless zones) using 2-wire polling bop
devices,
and/or
5700
or 5800
series
wireless
transnltfers.
Zones oan be distributed among up to 8 bgioal partitions
of operation.
%e Zones
Supports up to sixteen 2-wire smoke detectors (zone 1).
Other zones can be fire zones using 4-wire smoke and
heat detectors and/or polling loop detectors.
3utput Control
Supports up to 16 devices (4204 relay modules or X-1O
devices).
These devices can be put under schedule mntrol.
Remote Consoles
Supports up to sixteen addressable remote consoles
(6139, 5137AD, 4137AD).
Keyswitch
Supports the Ademco 4146 keyswitch.
Programming
Programming can be performed at the office prior to
installation, or on the job site directly from the console.
Can be downloaded from a remote location or at the job
site (using a PC/laptop with 41OOSMSerial Module) by
using the Ademco 4130PC Downloading Software.
The Control is pre-programmed with a set of standard
values that is designed to meet the needs of many
installations. These values, however, can be changed to
suit the needs of any particular installation.
The Control can also be pre-programmed by the installer
with one of four standard communication
default
programming values, thus further saving time and effort.
User Codes
Supports up to 128 user codes, maximum of 99 per
paftition
Panic Keys
Provides 3 panic key functions.
Communication
Ademco low speed, SESCOA/RADIONICS,
Ademco
Express, Ademco High Speed, Ademco Contact ID
Before Installing this partitioned system, become completely familiar
with the partitioning concepts, including zone distribution (each zone can be
assigned to only one partition), user code usage and authority levels, and the
user-friendly menu mode of programming. In addition, become familiar with the
scheduling and output relay features.
-5-