System-Wide - ADEMCO VISTA-50P Quick Start Manual

Partitioned security system with scheduling, step-by-step programming procedure, single and multiple partition programming forms system worksheets
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

(Duplicate this page for each partition in the installation.)
To program these fields,
1. Press *91 and select a partition.
2. Enter a partition-specific field number (ex. *09) and make the desired entry.
3. To access the 2nd and 3rd Page fields, press *94 to advance to the next higher level.
Then enter * + [last two digits] and make the desired entry. Press *99 to go to the next lower level.
4. Repeat steps 1 & 2 for each partition in the system.
5. Press *99 to exit programming from the 1st Page fields.
1st Page Fields
* 0 9
ENTRY DELAY #1
00-15 times 15 seconds
Maximum 3 for UL Listed installations.
* 1 0
EXIT DELAY #1
00-15 times 15 seconds
Maximum 4 for UL Listed installations.
* 1 1
ENTRY DELAY #2
00-15 times 15 seconds
Maximum 3 for UL Listed installations.
* 1 2
EXIT DELAY #2
00-15 times 15 seconds
Maximum 4 for UL Listed installations.
* 1 3
ALARM SOUNDER DURATION
01-15 times 2 minutes. Minimum 4 minutes for UL.
*16
CONFIRMATION OF ARMING DING
1=enable; 0=disable
* 2 2
KEYPAD PANIC ENABLES
1=enable; 0=disable
* 2 3
MULTIPLE ALARMS
1=yes; 0=no
* 2 9
QUICK ARM
1=yes; 0=no
* 3 2
PRIMARY SUBSCRIBER ACCT #
|
|
Enter 00-09; B-F (11-15) [15 15 15 15]
* 3 8
PREVENT ZONE XX BYPASS
01-86; 00 if all zones (except Fire zones) can be bypassed
* 3 9
ENABLE OPEN/CLOSE REPORT
FOR INSTALLER CODE
1=enable; 0=disable
* 8 4
SWINGER SUPPRESSION
01-15 alarms; Must be "00" (disabled) for UL.
* 8 5
ENABLE DIALER REPORTS
FOR PANICS & DURESS
1=enable; 0=disable
* 8 7
ENTRY WARNING
1=continuous; 0=3 beeps
* 8 8
BURG. ALARM COMM. DELAY
1=16 seconds; 0=no delay
* 9 0
SECONDARY SUBSCRIBER ACCT #
|
|
Enter 00-09; B-F (11-15) [15 15 15 15]
– 18 –
PARTITION-SPECIFIC FIELDS
PARTITION #____ PROGRAM FIELDS
[02]
[03]
[06]
[08]
[04]
[001]
95
96
|
|
[00]
[15]
[0]
95 96 99 Duress
|
|
2nd Page Fields
|
1 * 1 8
AFFECTS LOBBY
Enter 1 if this partition affects the common lobby;
enter 0 if it does not
|
1 * 1 9
ARMS LOBBY
Enter 1 if arming this partition attempts to arm lobby;
enter 0 if it does not
|
1 * 4 3
PERM. KEYPAD BACKLIGHT
1=enable; 0=disable When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
|
1 * 4 5
EXIT DELAY SOUNDING
1=enable; 0=disable Produces quick beeping during exit
delay if enabled.
|
1 * 4 7
CHIME ON EXTERNAL SIREN
1=enable; 0=disable
[0]
1 * 5 2
SEND CANCEL IF ALARM + OFF
1=no restriction; 0=within Bell Timeout period only
1 * 7 6
ACCESS CONTROL RELAY FOR PART.
99
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-16; 00=none
[1]
3rd Page Fields
2 * 0 5
AUTO-ARM DELAY
[1]
Enter the time between the end of the arming window and the
start of auto-arming warning period, in values of 01-14 times 4
minutes 00=instant; [15=no auto arm at all]. When this delay
expires, the Auto-Arm Warrning Period begins.
2 * 0 6
AUTO-ARM WARNING PERIOD
This is the time during which the user is warned to exit the
|
premises prior to the auto-arming of the system (beeps every
15 seconds; "ALERT" displayed). Enter 01-15 minutes.
00=instant at end of arming delay .
[0]
2 * 0 7
AUTO-DISARM DELAY
This is the time between the end of the disarming window and
auto-disarming. Enter 01-14 times 4 minutes; 00=instant at
|
end of window; 15=no auto-disarm.
2 * 0 8
ENABLE FORCE ARM FOR AUTO-ARM
0=disable; 1=enable
2 * 0 9
OPEN/CLOSE REPORTS BY EXCEPTION
1=enable; 0=disable; If enabled, only openings and closings
occurring outside the scheduled opening /
[1]
closing windows will trigger dialer reports. Opening reports
will also be suppressed during the closing window.,
[0]
2 * 1 0
ALLOW DISARMING ONLY DURING
ARMING/DISARMING WINDOWS
See system-wide field 2*11 if enabling field 2*10. This feature
adds high security to the installation.
0=disable; 1=enable
2 * 1 8
ENABLE GOTO FOR THIS PARTITION[0]
1=enable; 0=disable
2 * 2 0
ENABLE J7 TRIGGERS by PARTITION
1=enable for displayed partition; 0=disable for displayed
partition.
[0]
[0]
[0]
[0]
[0]
[0]
[0]
|
[15]
|
[00]
|
[15]
|
[0]
[0]
[0]
[1]