GENERATOR COIL RESISTANCE
• Remove the seat. (!5-3)
• Remove the fuel tank. (!4-2)
• Disconnect the generator coupler.
Measure the resistance between three lead wires.
If the resistance is not specified value, replace the stator with a
new one. Also, check that the generator core is insulated.
# 09900-25008: Multi circuit tester set
( Tester knob indication: Resistance (Ω Ω Ω Ω )
& Generator coil resistance: 0.4 – 0.8 Ω Ω Ω Ω (Black – Black)
NOTE:
When making above test, it is not necessary to remove the gen-
erator.
GENERATOR NO-LOAD PERFORMANCE
• Remove the seat. (!5-3)
• Remove the fuel tank. (!4-2)
• Disconnect the generator coupler.
• Start the engine and keep it running at 5 000 r/min.
Using the multi circuit tester, measure the voltage between three
lead wires.
If the tester reads under the specified value, replace the genera-
tor with a new one.
# 09900-25008: Multi circuit tester set
' Tester knob indication: Voltage (∼ ∼ ∼ ∼ )
& Generator no-load performance:
More than 60 V at 5 000 r/min (When engine is cold)
∞ ∞ ∞ ∞ Ω Ω Ω Ω (Black – Ground)