Address
Application
Decimal (Hex)
CH1
CH2
16396
16428
(400C
)
(402C
)
H
H
16397
16429
(400D
)
(402D
)
H
H
16398
16430
Predefined
(400E
)
(402E
)
H
H
protocol function
16399
16431
(400F
)
(402F
)
control data
H
H
16400
16432
specification
(4010
)
(4030
)
H
H
16401
16433
(4011
)
(4031
)
H
H
16402
16434
(4012
)
(4032
)
H
H
16403
16435
(4013
)
(4033
)
H
H
16404 to
16436 to
16415
16447
Use prohibited
(4014
to
(4034
to
H
H
401F
)
403F
)
H
H
Predefined
protocol function
16448
16464
(4040
)
(4050
)
control data
H
H
specification
16449
16465
(4041
)
(4051
)
H
H
Checking
predefined
protocol function
execution status
16450
16466
(4042
)
(4052
)
H
H
16451
16467
(4043
)
(4053
)
H
H
16452 to
16468 to
16463
16479
Use prohibited
(4044
to
(4054
to
H
H
404F
)
405F
)
H
H
16480 to 16517
Use prohibited
(4060
to 4085
)
H
H
16518(4086
)
H
16519(4087
)
H
Protocol setting
data error
information
16520(4088
)
H
16521(4089
)
H
App. - 16
Name
Matched receive packet No. 1
0: No matched receive packet
1 to 16: Matched receive packet No.
Matched receive packet No. 2
Matched receive packet No. 3
Matched receive packet No. 4
Matched receive packet No. 5
Matched receive packet No. 6
Matched receive packet No. 7
Matched receive packet No. 8
System area
Protocol cancel
0: No cancel instruction
1: Cancel request (set by user)
2: Cancel completed (set by C24)
Execution status
0: Unexecuted
1: Waiting for transmission
2: Sending
3: Waiting for data reception
4: Receiving
5: Completed
Predefined protocol function error code
0: Normal
Other than 0: Error (error code)
Number of protocol executions
0: No log
1 to 65535: Number of executions
System area
System area
Protocol No.
1 to 128: Protocol No.
65535: Unidentified
Setting type
0: Packet setting or element setting
1: Protocol detailed setting
65535: Not specified
Packet No.
0: Send packet
1 to 16: Receive packet
65535: Unidentified
Valid when the Setting type value is 0.
Element No.
1 to 32: Element No.
65535: Unidentified
Valid when the Setting type value is 0.
Initial
Protocol
Registration
value
MC Non Bi Pd
0
R
Not allowed
0
RW Not allowed
0
R
Not allowed
0
R
0
R
0
R
0
R
Not allowed
0
R
0
R
APPENDIXES
Reference
GX Works2
Version 1
Operating
Manual
(Intelligent
Function
Module)
Section 13.2
Section 15.2
Section 9.3
Section 15.2.2
App. - 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lj71c24Lj71c24-r2

Table of Contents