Mitsubishi Melsec-L Series User Manual page 121

Communication module
Hide thumbs Also See for Melsec-L Series:
Table of Contents

Advertisement

Item
Element Name
Fixed Length/Variable
Length
Data Length/ Maximum
Data Length
Unit of Stored Data
9 - 11
(5) Non-conversion Variable
Use this element to send the data in the device memory of a CPU module or
buffer memory as a part of a send packet, or store a part of a receive packet to
the device memory of a CPU module device or buffer memory.
The following lists the items.
Set a name of the element.
Fixed Length
Variable Length
Set the length of data to be sent and received.
(For the variable length data, set the maximum data length that can be specified to the data
length storage area.)
The range is 1 to 2048.
Lower Byte + Upper Byte
Lower Bytes Only
9 DATA COMMUNICATION USING THE PREDEFINED PROTOCOL
Description
Sends and receives the data whose length is fixed.
When sending: Specifies the data length at the time of the
protocol execution and sends data.
When receiving: Receives data of which the length is variable.
When sending: Sends each one word (2 bytes) data in the data
storage area in the order of the lower byte to the
upper byte.
When receiving: Stores the receive data to the data storage area
in the order of the lower byte to the upper byte.
When sending: Sends each lower byte of data in the data storage
area.
The C24 ignores data in the upper byte.
When receiving: Stores the receive data to each lower byte in the
data storage area.
The C24 stores 00
in the upper byte.
H
9 - 11