Mitsubishi Melsec-L Series User Manual page 344

Communication module
Hide thumbs Also See for Melsec-L Series:
Table of Contents

Advertisement

Address
Application
Decimal (Hex)
CH1
CH2
8944 (22F0
)
H
8945 (22F1
)
H
For callback
8946 (22F2
)
H
function
8947 (22F3
)
H
8948 (22F4
)
H
8949 to 8954
Use prohibited
(22F5
to 22FA
)
H
H
8955 (22FB
)
H
For the remote
password
function
8956(22FC
)
H
8957 to 8958
Use prohibited
(22FD
to 22FE
)
H
H
For the remote
8959(22FF
)
password
H
function
9216(2400
)
Use prohibited
H
For flash ROM
9217(2401
)
write count
H
housing
9218 to 9427
Use prohibited
(2402
to 25FF
)
H
H
9728 to 16383
For user
(2600
to 3FFF
)
H
H
Predefined
protocol function
16384
16416
(4000
)
(4020
)
control data
H
H
specification
16385
16417
Use prohibited
(4001
)
(4021
)
H
H
16386
16418
(4002
)
(4022
)
H
H
16387
16419
(4003
)
(4023
)
H
H
16388
16420
(4004
)
(4024
)
H
H
Predefined
16389
16421
protocol function
(4005
)
(4025
)
H
H
control data
16390
16422
specification
(4006
)
(4026
)
H
H
16391
16423
(4007
)
(4027
)
H
H
16392
16424
(4008
)
(4028
)
H
H
16393
16425
(4009
)
(4029
)
H
H
16394
16426
(400A
)
(402A
)
H
H
16395
16427
(400B
)
(402B
)
H
H
App. - 15
Name
Callback permit accumulated count
0 or more: Accumulated count
Callback denial accumulated count
0 or more: Accumulated count
Auto (callback) connection permit accumulated count
0 or more: Accumulated count
Auto (callback) connection denial accumulated count
0 or more: Accumulated count
Accumulated count of callback receive procedure cancel
0 or more: Accumulated count
System area
Accumulated count of unlock process normal completion
0 or more: Accumulated count of normal completion
Accumulated count of unlock process abnormal completion
processing
0 or more: Accumulated count of abnormal completion
System area
Accumulated count of lock process based on circuit disconnection
0 or more: Accumulated count of lock process based on circuit
disconnection
System area
Flash ROM write count
0 to 1000: Write count
System area
User setting area 2 (6656 words)
(Transmission/receiving data monitoring function default buffer)
Usage is determined by the user.
Number of continuous executions
0: Protocol unexecuted
1 to 8: Number of protocols to be executed continuously
System area
Execution result
0: Normal
Other than 0: abnormal (error code)
Result of the executions
0: Protocol unexecuted
1 to 8: Number of continuous protocol executions
Execution protocol No. designation 1
0: No instruction
1 to 128, 201 to 207: Protocol No.
Execution protocol No. designation 2
Execution protocol No. designation 3
Execution protocol No. designation 4
Execution protocol No. designation 5
Execution protocol No. designation 6
Execution protocol No. designation 7
Execution protocol No. designation 8
Initial
Protocol
Registration
value
MC Non Bi Pd
0
RW
Not allowed
0
RW
Not allowed
0
RW
Not allowed
0
R
Not allowed
0
RW
Not allowed
0
RW Not allowed
0
R
Not allowed
0
RW Not allowed
APPENDIXES
Reference
User's Manual
(Application)
User's Manual
(Application)
User's Manual
(Application)
App. - 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lj71c24Lj71c24-r2

Table of Contents