Mitsubishi Melsec-L Series User Manual page 342

Communication module
Hide thumbs Also See for Melsec-L Series:
Table of Contents

Advertisement

Address
Decimal (Hex)
Application
CH1
CH2
8260
8516
(2044
)
(2144
)
H
H
For designation
of programmable
controller CPU
monitoring
8261
8517
function
(2045
)
(2145
)
H
H
8262
8518
(2046
)
(2146
)
H
H
8263 to
8519 to
8268
8524
Use prohibited
(2047
to
(2147
to
H
H
204C
)
2149
)
H
H
8269
8225
(204D
)
(214D
)
H
H
8270
8226
(204E
)
(214E
)
H
H
8271
8527
(204F
)
(214F
)
H
H
8272
8528
(2050
)
(2150
)
H
H
8273 to
8529 to
8274
8530
(2051
to
(2151
to
H
H
2052
)
2152
)
H
H
8275
8531
(2053
)
(2153
)
H
H
8276
8532
(2054
)
(2154
)
H
H
For designation
of programmable
8277
8533
(2055
)
(2155
)
controller CPU
H
H
monitoring
function
8278
8534
(2056
)
(2156
)
H
H
8279
8535
(2057
)
(2157
)
H
H
8280
8536
(2058
)
(2158
)
H
H
8281 to
8537 to
8361
8617
(2059
to
(2159
to
H
H
20A9
)
21A9
)
H
H
8362 to
8618 to
8421
8677
Use prohibited
(20AA
to
(21AA
to
H
H
20E5
)
21E5
)
H
H
App. - 13
Name
Transmission pointer designation (For fixed cycle transmission and
data transmission)
0: No designation
1 to 100: Output head point (send from the nth)
Send the user frames designated in the following transmission
frame No. designation areas from the designated pointer position.
(addresses: CH1 side = BA
H
Output count designation (for fixed cycle transmission and data
transmission)
0: No designation
1 to 100:Output count (designate the number of frame transmissions.)
Data No. for connection designation (for fixed cycle transmission)
0: No designation
0BB8
to 0BD5
, 8001
to 801F
H
H
H
System area
Number of registered word blocks designation
0
: No designation
1 to 10: Number of blocks of word devices
Number of registered bit blocks designation
0
: No designation
1 to 10: Number of blocks of bit devices
Programmable controller
CPU abnormal monitoring designation
0: Do not monitor.
Monitoring device designation
0: No designation
90
to CC
: Device code
H
H
Head device No. designation
0 or more: Head device No.
Read point designation
0: No designation
1 or more: Number to read points
Monitoring condition designation (judgment condition
designation)
0: No designation
1 or more: Monitoring condition
Monitoring condition value designation
At bit device
0: OFF
No. 1
At word device 0 to FFFF
block
Transmission pointer designation (for condition
monitoring
agreement transmission and nonprocedural data
device
transmission)
0: No designation
1 to 100: Output head point (send from nth)
Send the user frames designated in the following
transmission frame No. designation areas from the
designated pointer position.
(address: CH1 side = BAH to 11DH, CH2 side = 15AH
to 1BDH)
Output count designation (for condition agreement
transmission and nonprocedural data transmission)
1 to 100: Output count (designate the number
of frame transmissions)
Data No. for connection designation (for condition
agreement transmission)
0BB8
to 0BD5
, 8001
H
H
Block
monitoring
The structure of each area is the same as the first block monitoring device area
devices
Refer to *1 for the details of each area.
No. 2 to
10
System area
to 11D
, CH2 side = 15A
to 1BD
H
H
: Data No. for connection
H
It is possible to
designate a
maximum of 10
blocks in total.
1: Monitor.
1: ON
: Monitoring condition value
H
to 801F
: Data No. for
H
H
connection
Initial
Protocol
Registration
value
MC Non Bi Pd
R
)
H
0
R
R
0
R
R
APPENDIXES
Reference
User's Manual
Allowed
(Application)
User's Manual
Allowed
(Application)
User's Manual
Allowed
(Application)
App. - 13