Mitsubishi Melsec-L Series User Manual page 255

Communication module
Hide thumbs Also See for Melsec-L Series:
Table of Contents

Advertisement

Item
Trace Result
Currently Displayed Data
Find Packet Data... button
Communication control signals
Open Trace File button
Save Trace File button
Close button
13 - 4
[Display/Setting screen]
[Display/Setting details]
Displays the model name, measurement time, and extraction date/time of
the module on which the circuit trace is executed.
Select the display format of the send/receive packets.
The hexadecimal or ASCII code can be selected.
The RS(RTS), ER(DTR), DR(DSR), CS(CTS), and CD(DCD) signal status
and receive error are displayed as described below.
• RS, ER, DSR, CS and CD signals
• Receive error
Reads and displays the trace data saved in the personal computer.
Saves the trace data obtained by the circuit trace to the personal
computer.
Closes the Circuit Trace screen.
Display/Setting details
All signals are displayed with blue lines -.
When signal is ON :
When signal is OFF :
When the obtained data does not have signal information, the signal is
displayed as an OFF status.
Three different errors of overrun error, parity error, and framing error are
displayed.
Overrun error:
(Green)
Parity error
:
(Light Blue)
Framing error:
(Purple)