Sequence program
CSET instruction
Complete device
Complete device+1
C24
Error
12 - 35
(4) The status of the CSET instruction, whether it is being executed or completed
normally/abnormally, can be checked by the complete device (D2) specified by
the setting data.
(a) Complete device ((D2) + 0)
This device turns on at the End processing of the scan at which the CSET
instruction is completed and turns off at the next End processing.
(b) Complete device ((D2) + 1)
It turns on/off by the status at which the CSET instruction is completed.
• At normal completion: It is kept turned off and does not change.
• At abnormal completion: It turns on at the END processing of the scan at
[Operation at execution of CSET instruction]
End
Scan
processing
Execution of instruction
Setting processing
(1) If the dedicated instruction is abnormally completed, the error flag (SM0) turns on
and the error code is stored in SD0.
Refer to the following according to the error code, and check/take action according
to the error.
<Error code>
4FFF
or less: MELSEC-L CPU Module User's Manual (Hardware Design,
H
Maintenance and Inspection)
7000
or later: Section 15.2
H
which the CSET instruction is completed and
turns off at the next END processing.
End
Scan
processing
At abnormal completion
12 DEDICATED INSTRUCTIONS
End
Scan
processing
12 - 35