Daikin VRV Plus Series General Information Manual page 86

R-407c
Hide thumbs Also See for VRV Plus Series:
Table of Contents

Advertisement

Si33-003.book Page 82 Monday, June 25, 2001 9:06 AM
Test Operation
4.12.4 Setting Contents and Code No. – VRV Unit
Mode No.
FIRST
Note)1
CODE No.
Filter Contamination-Heavy/
Light (Setting for display time
to clean air filter) (Sets display
0
time to clean air filter to half
when there is heavy filter
contamination.)
10(20)
Long-life filter type (Setting of filter sign indication
1
time) (Change setting when Ultra-long-life filter is
installed)
2
Thermostat Sensor in Remote Control
Display Time to Clean Air Filter Calculation (Set
3
when filter sign is not to be displayed)
Optional accessories output selection (field
0
selection of output for adaptor for wiring)
ON/OFF Input from Outside (Set when ON/OFF is
1
to be controlled from outside.)
12(22)
Thermostat Differential Changeover (Set when
2
remote sensor is to be used.)
Automatic mode differential (automatic
4
temperature differential setting for VRV system
heat recovery series cool/heat)
5
Power failure automatic reset (Auto Restart)
High Air Outlet Velocity (Set when installed in a
0
place with ceiling higher than 2.7m.)
Selection of Air Flow Direction (Set when a
1
blocking pad kit has been installed)
Air Flow Direction Adjustment (Set at installation of
13(23)
3
decoration panel.)
4
Field set air flow position setting
Field set fan speed selection (fan speed control by
5
air discharge outlet for phase control)
1
Humidifying with thermostat OFF
15(25)
3
Drain Pump humidifier interlock selection
Notes:
1. Setting is carried out in the group mode. however, if the mode number inside the parentheses is
2. The SECOND CODE number. is set to "
3. Do not make any settings not given in the table above.
4. Not displayed if the indoor unit is not equipped with that function.
5. When returning to the normal mode. "88" may be displayed in the LCD in order for the remote control to
82
Description of Setting
Ultra-Long-Life
Type
Long-Life Type
Standard Type
FXYC, FXYF, FXYK, FXYH only
FXYF only
FXYK only
selected, indoor units can also be set individually.
initialize itself.
SECOND CODE NO. Note)2
01
02
Approx.
Approx.
10,000
5,000
hours
hours
Approx.
Approx.
2,500
1,250
hours
hours
Approx.
Approx.
200 hours
100 hours
Long-Life
Ultra-Long-
Filter
Life Filter
Use
Not Use
Do not
Display
Display
Indoor Unit
Operation
Turned ON by
Output
Thermostat
External
ON/OFF
Forced Off
Protection
Control
Device
1˚C
0.5˚C
01 : 0 02 : 1 03 : 2 04 : 3 05 : 4 06 : 5 07 : 6 08 : 7
No equipped
Equipped
N
H
F
T
(4 directions)
(3 directions)
(2 directions)
Equipped
Not Equipped
Draft
Ceiling Soiling
Standard
Prevention
Prevention
Optional
Optional
Standard
Accessory 1
Accessory 2
Not Equipped
Equipped
Not Equipped
Equipped
" when shipped from the factory.