Daikin VRVIII Series Technical Data Manual

Air conditioning systems bs box
Hide thumbs Also See for VRVIII Series:

Advertisement

EEDEN08-200
technical data
BS box
BSVQ-P8B
2a

Advertisement

Table of Contents
loading

Summary of Contents for Daikin VRVIII Series

  • Page 1 EEDEN08-200 technical data BS box BSVQ-P8B...
  • Page 2: Table Of Contents

    • BS Units • BS UNITS • BSVQ100-250P8B TABLE OF CONTENTS BSVQ100-250P8B Specifications ............2 Technical Specifications .
  • Page 3: Specifications

    • BS Units • BS UNITS • BSVQ100-250P8B Specifications 5 0 P 0 - 2 t e m Q 1 0 S y s V R V B S V 1-1 TECHNICAL SPECIFICATIONS BSVQ100PV18 BSVQ160PV18 BSVQ250PV18 Power input Cooling 0.005 0.005 0.005 (nominal)
  • Page 4: Safety Device Settings

    • BS Units • BS UNITS • BSVQ100-250P8B Safety device settings BSVQ-P8 PC BOARD FUSE 250V 3.15A 4D057956A Options BSVQ100-250P8 OPTION LIST BSVQ100P BSVQ160P BSVQ250P Item PCB for multi tenant DTA114A61 4TW31159-1 All options are kits. ® • VRV Systems • BS Units...
  • Page 5: Dimensional Drawing & Centre Of Gravity

    • BS Units • BS UNITS • BSVQ100-250P8B Dimensional drawing & centre of gravity 4 - 1 Dimensional drawing BSVQ250PV1 (Suspension bolt pitch) 300 or more 300 or more (Servicing space) (Servicing space) Servicing space Name Description Suction gas pipe connection port ø22.2mm brazing connection HP/LP gas pipe connection port ø19.1mm brazing connection...
  • Page 6 • BS Units • BS UNITS • BSVQ100-250P8B Dimensional drawing & centre of gravity 4 - 1 Dimensional drawing BSVQ100PV1 (Suspension bolt pitch) 250 or more 250 or more 300 or more (Servicing space) (Servicing space) (Servicing space) (In case of use attached pipe) Servicing space Name Description...
  • Page 7: Centre Of Gravity

    • BS Units • BS UNITS • BSVQ100-250P8B Dimensional drawing & centre of gravity 4 - 2 Centre of gravity BSVQ100,160PV1 In case of the electrical box on the standard side of the unit In case of the electrical box on the other side of the unit 3D058131 BSVQ250PV1 In case of the electrical box on the standard side of the unit...
  • Page 8: Piping Diagram

    • BS Units • BS UNITS • BSVQ100-250P8B Piping diagram BSVQ-P8 Liquid pipe connection port Liquid pipe connection port Electric Double pipe heat Expansion Valve exchanger (EVSC) Filter Capillary tube Electric Expansion Valve HP/LP gas pipe connection port (EVHS) Filter Electric Expansion Valve HP/LP gas pipe connection port...
  • Page 9: Wiring Diagram

    • BS Units • BS UNITS • BSVQ100-250P8B Wiring diagram 6 - 1 Wiring diagram BSVQ-P8 Note 5 BS unit top Note 2 Power supply Indoor unit Outdoor unit Printed circuit board Electric Expansion Valve (Sub Discharge) DS1, DS2 Dip Switch Electric Expansion Valve (Sub Suction) Fuse (T, 3, 15A, 250V) Electric Expansion Valve (Main Discharge)
  • Page 10: Sound Data

    • BS Units • BS UNITS • BSVQ100-250P8B Sound data 7 - 1 Sound pressure spectrum BVSQ100P8 BVSQ160P8 Operating sound Operating sound Stoppage sound Stoppage sound (note 5) (note 5) Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz)
  • Page 11 The present publication is drawn up by way of information only and conditioning equipment, compressors and Quality Management System in accordance with the does not constitute an offer binding upon Daikin Europe N.V.. Daikin refrigerants has led to its close involvement in ISO9001 standard. ISO9001 pertains to quality Europe N.V.

This manual is also suitable for:

Bsvq250pv18Bsvq-p8b seriesBsvq100pv18Bsvq160pv18

Table of Contents