Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
RSXYP30KJ
Daikin RSXYP30KJ Manuals
Manuals and User Guides for Daikin RSXYP30KJ. We have
2
Daikin RSXYP30KJ manuals available for free PDF download: Service Manual, General Information Manual
Daikin RSXYP30KJ Service Manual (255 pages)
Brand:
Daikin
| Category:
Inverter
| Size: 9.8 MB
Table of Contents
General
3
Table of Contents
3
What I a VRV System?
6
What Is a VRV System
6
List of VRV Unit Models
7
List of Outdoor Unit Models
7
Nomenclature
9
System Basic Configuration
15
Cooling / Heating Selection -Standard- System
15
Heat Recovery (Cooling / Heating Individual Operating) System
18
Super Wiring System
19
Points of Super Wiring System
19
Wiring Length
20
REFNET Piping
21
Allowable Length of Refrigerant Piping
21
For Refrigerant Piping
23
B. Basic Informationb. Basic Informationb. Basic Informationb. Basic Information
25
B. Basic Information
25
1 Explanations on P-H Diagram (Refrigerant Characteristics Table)
26
2 Concept of Basic Refrigeration Cycle
27
3 Points of Refrigerant Control of VRV System
28
Cooling Operation
28
Heating Operation
29
Compressor Capacity Control
30
Control of Electronic Expansion Valve
31
4 Control of Indoor Unit
32
Thermostat-Control
32
Drain Pump Control
34
Freeze-Up Prevention Control
35
Heater Control
36
Thermostat Control in Cooling / Heating Automatic Operation
37
5 Other Functional Operations
39
Explanations on Main Functional Control
39
Explanations on Electric and Functional Components
40
C. Field Settings from Remote Controller
45
1 Field Settings from Remote Controller
46
Field Setting Mode
47
Service Mode
53
Check Mode
58
Test Operation Mode
59
2 Field Setting on Outdoor Unit
60
Explanation of Basic Mode
61
Use of each Setting Mode
67
D. Troubleshootingd. Troubleshooting
71
D. Troubleshooting
71
1 For Troubleshooting
72
2 Check Items before Troubleshooting
73
Check Items on Operation Condition (Essential Items as a Minimum)
73
Check for Malfunction in Cooling Operation
74
Check for Malfunction in Heating Operation
75
3 Method of Troubleshooting
76
Excessive / Insufficient Charging of Refrigerant
76
Troubleshooting
78
Abnormal Judgment for Various Sensors
79
Structure and Operation of Electronic Expansion Valve
87
Structure and Movements of Four-Way Valve
89
Structure and Operation of Solenoid Valve
91
Structure and Operation of Two-Way Solenoid Valve
92
Check on Outdoor Fan Motor
93
Diagnosis on Malfunction Code of Inverter System
94
Diagnosis on Transmission System Malfunction
97
4 Malfunction Tree Analysis (FTA)
100
Actuation of Freeze-Up Prevention Control of Indoor Unit
101
Actuation of HPS in Heating Operation
102
Abnormal Discharge Pipe Temperature in Cooling Operation
103
Water Leakage from Indoor Unit
104
Defective Lubrication of Compressor
105
5 List of Malfunction Code
106
6 Operating Condition Check Sheet
112
E. Cases for Examination
113
F. Service Checker Type3F. Service Checker Type3 Application Edition
131
1 List of Applicable Models of TYPE3
132
VRV Multi Systems (R410A/R407C/R22)
132
2 What Service Checker Can Do
134
3 Recording and Playback of Operation Data
141
Menu Window (Map Mode)
141
Periodical Recording Setting Window
143
Centralized Operation (F7)
146
Display of Operation Data
146
Playback of Data Recorded
148
4 Collection and Playback of Data on Checker
150
Retrieval of Raw Data
151
Retrieval of Processed Data
153
Data Processing
155
Organizing Graph
172
Using Secondary Axis
174
Traverse of X Axis
176
5 Points of Analysis
182
Method of Use by Symptom
182
To Conduct Analysis
182
Effective Use of Checker
184
Example of Checker Connection
185
Method of Mounting Sensor Kit
186
Place to Save Data
187
G. Appendixg. Appendix
195
G. Appendix
195
1 Characteristics of Refrigerant
196
R22
196
R407C
197
R410A
199
2 Psychrometric Chart
201
3 How to Calculate Cooling / Heating Capacity
202
4 Field Settings for the Replacement of the Spare Control PC Board
203
5 Adaptors for Connection of Air Conditioners
205
Wiring Adaptor for Electrical Appendices (2) <KRP4A51, 52, 53, 54
205
Wiring Adaptor for Electrical Appendices (1) (KRP2A61, 62)
213
External Control Adaptor of Outdoor Unit
220
Dta104A53, 61, 62
220
DIII-NET Expander Adaptor <DTA109A51
225
System Configuration
225
Versatile Usage
229
6 How to Replace the Compressor
232
7 HRV-Related
233
Group Interlock Control
233
Centralized Control System
238
Examples of Mistakes in Wiring and System Designing
240
Indoor Unit
240
Additional Functions
241
Central Control System (DCS302B61)
246
Advertisement
Daikin RSXYP30KJ General Information Manual (198 pages)
R-407C
Brand:
Daikin
| Category:
Air Conditioner
| Size: 11.85 MB
Table of Contents
Table of Contents
1
Part 1 General Information
5
Product Outline
6
Year 2000 Models Using New Refrigerant
6
Outline of New Series Products
7
Sie33
7
Model Configuration and Combination
9
Points to Bear in Mind at the System Design
10
Points Relating to the Performance of the Air Conditioning Units
10
The Installation Is of Vital Importance
11
Striking a Balance between System Installation and General Construction Work (Comprehensive Flow Chart)
12
Points to Bear in Mind When Preparing the Contract Drawings
13
Installation
16
Step by Step Installation Procedure
16
Work Involved in Individual Operations and Points to be Borne in Mind
17
Operational Steps
17
Selection of Location
59
Additional Refrigerant Charge Operation
81
Appendix
96
Allowable Piping Length
98
Selection of Refrigerant Pipe Size
99
Additional Charge of Refrigerant
101
REFNET Pipe Connections for VRV R-407C PLUS Series
104
Introduction
128
Cautions in Installation
129
Combination
130
Standard Operation Limit
131
Standard Supplied Accessories
132
Optional Accessories
133
Technical Specifications
134
Electrical Specifications
135
Main Components
136
Selection of Location
137
Inspecting and Handling the Unit
138
Unpacking and Placing the Unit
139
Refrigerant Piping
140
Selection of Piping Material
141
Connecting the Refrigerant Piping
142
Leak Test and Vacuum Drying
147
Pipe Insulation
148
Additional Refrigerant Charge
149
Field Wiring
151
Internal Wiring
152
Optional Parts Cool/Heat Selector
154
Power Circuit and Cable Requirements
155
General
156
Examples
157
Before Operation
162
Checks before Initial Start-Up
162
Test Run
163
Caution for Refrigerant Leaks
167
Precautions in Servicing the Models with New-Type Refrigerant
170
Tools Required
170
Notes for Work Procedures
171
Changes Required by New Refrigerants
172
Changes Required by New Refrigerant
172
Refrigerant and Refrigerant Oil Characteristics
173
Refrigerant Characteristics
173
Refrigerant Oil Characteristics
175
Refrigerant Cylinders
176
Cylinder Specifications
176
Handling of Cylinders
177
Service Tools
178
Tool Compatibility
178
New Tools Required for Hfcs and Reasons of Change
179
Cautions During Service Operations (Changes Required by New Refrigerants)
182
The Three Basic Rules for Refrigerant Piping Must be more Strictly Observed
182
Operation Guideline
183
Temperature-Pressure Conversion Table for New Refrigerants
184
Pressure and Temperature
184
Measures to Take in the Case of Gas Leaks
185
Gas Shortage
185
Measure for Gas Shortage
186
Safety Precautions
187
Problems Resulting from Negligence of Caution Items
188
Difference between Pascal and Conventional Pressure Unit
189
Comparison of Mpa and Kgf/CM²
189
Thermodynamic Characteristic Charts (HFC407C)
190
Thermodynamic Characteristics of R-407C
190
Index
193
Advertisement
Related Products
Daikin RSXYP8KJY1
Daikin RSXYP10KJY1
Daikin RSXYP5KJY1
Daikin RSXYP16KJ
Daikin RSXYP20KJ
Daikin RSXYP18KJ
Daikin RSXYP26KJ
Daikin RSXYP28KJ
Daikin RSXYP24KJ
Daikin RSXY5KYAL
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL