Command
Information Requests (continued)
View internal temperature
Set verbose mode
View verbose mode
KEY:
X1@
= Internal temperature
X3$
= Verbose mode (see the
command description
more information)
IP Control Port Commands
IP Setup
NOTES:
Changes made to any TCP/IP settings do not take effect until the reboot network command (
The following IP address setup commands that are followed by
issue them without Administrator status result in an E24 (privilege violation) error message.
Set DHCP mode
24
View DHCP mode
Set IP address
24
Read IP address
Set subnet mask
24
View subnet mask
Set gateway IP address
24
View gateway IP address
KEY:
X1)
=
On or off, enable or disable
X6$
= Port timeout
X8&
=
IP address
X8*
=
Gateway address
X8(
=
Subnet mask
X9#
=
Subnet mask in CISG commands
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
ASCII Command
Response
(Host to Scaler)
(Scaler to Host)
E
}
X1@]
20STAT
Verbose modes 2 and 3:
20Stat•
EX3$
}
X3$]
CV
Vrb
E
}
X3$]
CV
In degrees Celsius. Response is two digits, padded with a zero.
verbose mode
0 = None (default for LAN connection)
1 = Verbose mode (default for RS-232 and USB connection)
on page 58 for
2 = Tagged responses to queries
3 = Verbose mode and tagged responses
E X1)
}
DH
Idh
E
}
X1)]
DH
E X8&
}
CI
Ipi
E
}
X8&]
CI
E X8(
}
CS
Ips
E
}
X8(]
CS
E X8*
}
CG
Ipg
E
}
X8*]
CG
0 = DHCP disabled (default), 1 = DHCP enabled
Time in increments of 10 seconds before the port connection times out.
1 (10 seconds) through 65000 (650,000 seconds)
Default = 30 (300 seconds)
Format nnn.nnn.nnn.nnn (192.168.254.254 = default)
Leading zeros in each of the four octets are optional in setting values,
and are suppressed in returned values.
nnn.nnn.nnn.nnn (0.0.0.0 = default)
nnn.nnn.nnn.nnn (255.255.255.0 = default)
Prefix representing subnet mask bits (subnet mask value in CISG
commands).
Default = /24, which represents the default subnet mask,
255.255.255.0.
Additional Description
View unit internal temperature
degrees Celsius.
X1@ ]
Set the verbose mode to
or disable tagged responses (additional
information provided in response to a
query).
View the current verbose mode.
require Administrator permission to enter. Attempts to
24
X1)]
Enable or disable DHCP.
View the DHCP mode setting.
• X8&]
Set the IP address to
View the current IP address.
• X8(]
Set the subnet mask to
View the subnet mask setting.
• X8*]
Set the gateway IP address to
View the gateway IP address setting.
X1@
in
X3$
and enable
E
}
2BOOT
) is issued.
X8&
.
X8(
.
X8*
.
82