Front panel configuration port — Connect a host device to the USB mini-B port for
A
device configuration, control, and firmware upgrades.
Input selection buttons — (1 through 6 on IN1806, 1 through 8 on IN1808 Series)
B
Press one of these buttons to select an input. The buttons light amber for audio and
video, green for video only, or red for audio only.
Logo button — Press this button to enable or disable the most recently selected logo.
C
Press and hold the button to select the logo in the desired slot, using the input selection
buttons:
IN1806 — Slots
1
commands and PCS).
IN1808 series — Slots
commands and PCS).
See
Selecting a Logo
Status LED indicators
D
Input signal LEDs — These eight LEDs light green for their corresponding inputs
when active video content is detected on that input.
Output signal LEDs — Output LEDs 1A, 1B, and Loop light green when active
video is being output, and blink amber when output video and sync are disabled.
Input HDCP LEDs — These eight LEDs light green for each input signal that is
HDCP-encrypted.
Output HDCP LEDs — These three LEDs light green for an output when it is
currently HDCP-encrypted.
DTP2 and DTP Input LEDs — These two LEDs light green if DTP or DTP2 power
has been enabled on the corresponding input.
DTP2 and DTP Output LEDs — These Output LEDs light green if DTP or DTP2
power has been enabled on DTP output 1B.
Menu and Enter buttons — Press these buttons to access and navigate the
E
on-screen display menu system.
Navigation buttons — Press these buttons to navigate through the on-screen display
F
menu system or change settings.
Mic and Volume knobs and LED indicators — Rotate the
G
microphone level. Rotate the
(configurable, see the IN1806 and IN1808 Series PCS Help File for more information).
The eight LED indicators for each knob light according to the level being adjusted. The
LEDs light in order from bottom to top to indicate steps from 0% to 100% of the set
limits. The LEDs blink when levels are approaching the lower or upper limits.
IPCP Pro LED indicators (IPCP models only) — These LEDs light to indicate
H
status of the IPCP module ports (see the IPCP Pro Series User Guide, available at
www.extron.com, for details).
IN1806 and IN1808 Series Scaling Presentation Switchers • Operation
through
(slots 7 through 16 are available only via SIS
6
through
(slots 9 through 16 are available only via SIS
1
8
on the next page for more information.
knob to adjust the program or output volume level
Volume
knob to adjust the
Mic
24