Extron electronics IN1806 Series User Manual page 26

Scaling presentation switchers, scalers
Table of Contents

Advertisement

IPCP control processor (IN1808 IPCP SA and IN1808 IPCP MA 70 only) — The
Q
IN1808 IPCP models include a built-in IPCP Pro 355M Control Processor (see
and 6
on page 13). For these models, the LAN connector is incorporated in the IPCP
control processor. For connection and installation details of this control processor, see
the IPCP Pro Series User Guide at www.extron.com.
The IPCP module contains the following:
1
COM 1
Tx Rx
G
RTS CTS
IR/SERIAL
1
2
R
R R R R R R R R R R R R R R R R R R R R R R R
S
G
S
G
8
9
COM 1 Port
1
COM 2 and COM 3 ports
2
Digital I/O port
3
Figure 9.
IPCP Control Module (IPCP Models Only)
The IPCP module ports are configurable via Global Configurator (GC) software, available
at www.extron.com.
COM 1 port — 5-pole captive screw bidirectional RS-232/RS-422/RS-485 port for
1
Tx/Rx/G/RTS/CTS
COM 2 and COM 3 ports — Bidirectional 3-pole captive screw RS-232 ports for
2
Tx/Rx/G
Use the COM ports for serial control of a display or other device and to receive status
messages from the connected devices.
Digital I/O ports — 5-pole captive screw connector, supporting four TTL level
3
digital inputs or outputs, with or without +5 VDC pull-up. Connect switches,
sensors, LEDs, relays, or similar items to these ports, which enable monitoring of
connected devices and trigger functions on the control processor.
AV LAN ports 1 - 3 — Network switch with its own network interface that keeps
4
the AV subnetwork separate from the corporate network for security purposes and
to reduce traffic on the corporate or outside network.
To connect the IPCP to an Ethernet network (for configuration and control of the
IPCP module and the devices connected to it), connect an internet cable between
any of these RJ-45 sockets and a network switch, hub, router, or PC connected to
a local network or the Internet.
AV LAN ports 1 - 3 use a separate network interface from that of the LAN port.
NOTE: A dedicated AV LAN safeguards AV systems from outside intrusion
or interference by separating device control and other network traffic from a
corporate or campus network. To ensure the control processor LAN and AV
LAN connections (ports) are connected to separate networks, the LAN and AV
LAN IP address schemes must be on different subnetworks.
IN1806 and IN1808 Series Scaling Presentation Switchers • Installation
2
3
COM 2
COM 3
DIGITAL I/O
Tx Rx G
Tx Rx G
1 2
3
4 G
RELAYS
eBUS
1
2
C
3
4
C
+V
+5
-5
G
PWR OUT = 6W
7
6
AV LAN ports
4
LAN port
5
eBUS port
6
figures 5
4
AV LAN 2
AV LAN 3
LAN
AV LAN 1
5
4
Relay ports
7
IR/Serial ports
8
Reset button and LED
9
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

In1808 seriesIn1806In1808In1808 ipcp saIn1808 ipcp ma 70

Table of Contents