SIS Configuration
and Control
The IN1806 and IN1808 Series scalers can be configured and controlled via Extron Simple
Instruction Set (SIS) commands when connected to a host computer or other device
(such as a control system). Attach the host device to the rear panel RS-232 connector
or LAN connector, or to the front panel USB port. Commands can be entered using a
Telnet application such as the Extron DataViewer, available at
DataViewer Help file for more details). The default protocol for the RS-232 connection is
9600 baud, 8 data bits, 1 stop bit, no parity, and no flow control. This section describes SIS
communication and control. Topics in this section include:
•
•
•
Host and Scaler Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the scaler determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the scaler to the host end with a carriage return and a line feed
(CR/LF = ] ), indicating the end of the response character string (one or more characters).
Copyright Messages
The copyright message is displayed upon connecting to a scaler via TCP/IP or Telnet or
after a power cycle via RS-232, and depends on the scaler model.
]
60-16nn-0n
Ddd, DD MMM YYYY HH:MM:SS
•
•
•
•
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
Host and Scaler Communication
SIS Overview
Command and Response Tables for SIS Commands
(c) Copyright YYYY, Extron Electronics, IN180n <model>, Vn.nn,
]
] (day, date, and time as in
is the year.
YYYY
<
>, if applicable, is
model
IPCP SA
is the model part number:
60-16nn-0n
• IN1806 —
60-1663-01
• IN1808 base model —
60-1615-01
• IN1808 IPCP SA —
60-1615-02
• IN1808 IPCP MA 70 —
is the firmware version number.
Vn.nn
or
IPCP MA 70
60-1615-03