Extron electronics IN1806 Series User Manual page 89

Scaling presentation switchers, scalers
Table of Contents

Advertisement

Command
Backup and Restore Configuration
Save unit configuration
Restore unit configuration
KEY:
X8%
= Configuration type
NOTE:
Configuration files are stored in the directory /nortxe-backup, created on the unit by the Save command.
Information Requests
General information
Query model name
Query unit description
Query firmware version
Query full firmware version
Query part number
KEY:
X!
= Input selection
X#
= Digital video format
X1)
= On or off, enable or disable
X1#
= Horizontal and vertical frequencies
X3%
= Model name
X3^
= Part number
X4@
= Video output mute
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
ASCII Command
Response
(Host to Scaler)
(Scaler to Host)
E
X8%
}
1*
XF
Cfg1*
E
X8%
}
0*
XF
Cfg0*
0 = IP configuration (ip.cfg)
2 = Unit-specific parameters (box.cfg)
X!
X!
*I
Vid
Verbose modes 2 and 3:
Inf00*Vid
X3%]
1I
Verbose modes 2 and 3:
Inf01*
2I
Scaling•Presentation•Switcher
Verbose modes 2 and 3:
Inf02*Scaling•Presentation•Switcher
Q
n.nn
Verbose modes 2 and 3:
Ver01*n.nn
*Q
n.nn.nnnn
Verbose modes 2 and 3:
Bldn.nn.nnnn
X3^]
N
Verbose modes 2 and 3:
X3^]
Pno
1 = DisplayPort input 1 (all models)
2-6 = HDMI or DVI inputs 2 through 6 (all models)
7-8 = DTP2/XTP inputs 7 and 8 (IN1808 Series only)
9 = Aux audio input
0 = No signal, 1 = DVI, 2 = HDMI, 3 = DisplayPort
0 = Audio unmuted, 1 = Audio muted
nnn.nn. Response is three digits with two decimal places.
IN1806, IN1808, IN1808 IPCP MA, or IN1808 IPCP SA
IN1806 — 60-1663-01
IN1808 (base model) — 60-1615-01
IN1808 IPCP SA — 60-1615-02
IN1808 IPCP MA 70 — 60-1615-03
0 = Unmuted, 1 = Muted to black screen, 2 = Muted video and sync
Additional Description
X8%]
Back up the current unit configuration as
type
X8%]
Restore the saved configuration, type
X8%
.
X#
X1)
X4@
•Typ
•Amt
•Vmt
•Hrt
X!
X#
X1)
•Typ
•Amt
•Vmt
View video input signal type, audio mute
status, video mute status, and horizontal
and vertical frequencies.
View the unit model name (
X3% ]
View the IN1806 or IN1808 Series
product description.
]
View the unit firmware version to the
second decimal place.
]
]
View the unit firmware version with its
build number.
]
View unit part number
X8%
to a file in the unit file system.
X1#
X1#]
•Vrt
X4@
X1#
X1# ]
•Hrt
•Vrt
X3%
).
]
]
X3^
for the model.