Incorrect Mounting Of The P Sensors - Roland R1000 Series Manual

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Mounting
4.3.7

Incorrect mounting of the P sensors

The following illustration shows examples of incorrect installations of P-sensors.
Fig. 29: incorrect mounting of the p sensors
Pos : 36 /D oppel blech/Geräte/E20 Bus/4 M ontage/El ektr omag netische Störungen @ 0\mod_1173692244625_501.doc @ 3389 @ 3 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
60
Double Sheet Detector R1000 series E20
Faulty!
The sensor does not touch the sheet.
Faulty!
The sensor does not sit perpendicular on the sheet, the sensor bracket is
apparently not suitable.
Faulty!
An air gap exists between the first and the second sheet.
The sensor is mounted in an unfavourable position.
Faulty!
An air gap exists between the first and the second sheet.
The second sheet clings to the first sheet, perhaps by stamping residuals.
Faulty!
Fault prone control in a bucket. An air gap exists between bended sheets.
Manual
B0046991 / Rev. 1.6