Cable shields must be connected according to the wiring diagram (For details refer to chapter 5.4)
and should have no additional connections.
Instruction: Leading a cable through EMC gland
Remove outer PVC sheath and shield but leave enough length for sheath and leads.
Circular cut of outer PVC sheath after about 20 mm, but do not remove
Move cable through the gland
Remove outer sheath
Pull cable back until the shield and the contact springs inside the PG-gland connect.
Close PG-gland
Fig. 8: Connecting cable to PC-gland
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
Damaged cable isolation can cause further (unwanted) electrical
Note
connections.
Kabelabschirmung
Cable shield
Manual
20mm