Control Unit - Roland R1000 Series Manual

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046991 / Rev. 1.6
3.3

Control unit

The E20 is based on the product platform R1000.
Major features of the control unit:
Programmable for 255 different sheet thicknesses and materials
Calibration by a Teach-In procedure
Digital display of sheet thickness and operating parameters
Monitoring of over gauge and under gauge limits
Monitoring of operating voltage and cable break as well as shortcut at sensor cable
Optocoupler for direct I/O control via the PLC for fast measurement operations
Data backup via serial interface
Pos : 22 /D oppel blech/Geräte/E20/3 Sys tembeschr eibung/Parameter des Aus wer teger ätes @ 1\mod_1192534880062_501.doc @ 5043 @ 233 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
Manual
System description
31