Wiring Diagram Version C, Opto Coupler Outputs - Roland R1000 Series Manual

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046991 / Rev. 1.6
5.4.5

Wiring diagram Version C, opto coupler outputs

PLC
P LC earth ground
P LC earth ground
P 42A ,P30
(P75V)
P -S ensor 2
P 42A ,P30
(P75V)
P -S ensor 3
P 42A ,P30
(P75V)
P -S ensor 4
P 42A ,P30
(P75V)
Complete wiring is required only if all options are to be used.
The highlighted areas are relevant only for the 4P versions.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
LiYCY 10 x 0,25 mm²
Shield
PLC / COM
Measurement Start
Bit 0
(Teach-In)
Bit 1
(Zero adjust)
Bit 2
Meas menue select.
Bit 3
System test
Bit 4
Bit 5
Bit 6
Bit 7
Sensor select. A
Sensor select. B
+24 VDC / PLC
Shield
LiYCY 17 x 0,25 mm²
1 (5)
1 (5)
black (2) [brown]
2 (6)
2 (6)
black (1) [white]
- ( )
5 ( )
O ILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CS A)]
1 (5)
1 (5)
black (2) [brown]
2 (6)
2 (6)
black (1) [white]
- ( )
5 ( )
O ILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CS A)]
1 (5)
1 (5)
black (2) [brown]
2 (6)
2 (6)
black (1) [white]
- ( )
5 ( )
O ILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CS A)]
1 (5)
1 (5)
black (2) [brown]
2 (6)
2 (6)
black (1) [white]
- ( )
5 ( )
O ILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CS A)]
+ 24 VDC
external
power supply
0 VDC
Central machine ground
The positive supply voltage +24 VDC should not be connected to
Attention
machine ground.
Manual
R1000
1
2
3
32
PLC/CO M
4
PLC/CO M
5
IN0
6
IN1
7
IN2
8
IN3
33
IN4
34
IN5
35
IN6
36
IN7
37
IN8
30
IN9
31
IN10
9
+
Out 0
10
-
Enable
+
11
Out 1
12
-
2-Sheets
+
13
Out 2
14
-
1-Sheet
15
+
Out 3
16
-
0-Sheet
Max. 250 VAC / 1A
21
20
19
Shield
25
24
Shield
27
26
Shield
29
28
Shield
23
22
17
LiCY 2 x 1 mm²
18
Earth ground
R1000
>= 1,5 mm²
Electrical installation
71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E20

Table of Contents