Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Start-up
Then press the ENTER key.
The Teach-In measurement value is then displayed:
program par.
TI val.:
Fig. 53: Teach-in measurement value
This measured value can be accepted or changed, e.g. to calibrate the control unit.
The teach-in procedure is now completed (for a 1P system).
Description of the Teach-in procedure:
With system parameter 3:
Step 1: attach sheet to
sensor and initiate
teach-in
Step 2: Calibration
I.
Maximum possible correction is double the displayed value, however, not more than 133% of the nominal
thickness and not more than the max. measurable thickness (depends on sensor size), under gauge correction is
max. 75% of the displayed value, however not less than 50% of the nominal dimension
II.
Unlimited, displayed value must be larger than 0.05 mm and smaller than the max. measurable thickness
(depends on sensor size)
III.
+100% / -25% related to the measured thickness. If this correction range is not sufficient, in order to reach the
nominal dimension, an error message is generated
The Teach-In affects only the selected program.
Pos : 59 /D oppel blech/Geräte/E20/7 Inbetriebnahme/Parameter (Sys tem-) @ 1\mod_1192448722578_501.doc @ 4928 @ 2 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
108
Double Sheet Detector R1000 series E20
7
0.97mm
For a 4P system with sequential measurement the entire teach-in
Attention
procedure for all sensors is performed in the selected sequence. For
sensor selection A/B the teach-in for the selected sensor is then
competed. However, if all sensors should be taught, then the teach-in
of the other sensors must be repeated separately.
Locally at the control unit
mm or inch
measured value is
displayed
change displayed
value to actual
value (e.g. as
measured with a
micrometer)
Max. possible
correction see I.
Manual
%mm or inch
mm or inch
measured value is
displayed
displayed value is
measured thickness
transferred as
is changed to
nominal thickness
nominal thickness
(100%) to the
program
Max. possible
Max. possible
correction see II.
correction see III.
B0046991 / Rev. 1.6
With PLC (parallel or fieldbus)
%mm or inch
– –
– –
measured thickness
is transferred as
nominal thickness
(100%) to the
program
Max. possible
correction see II.