Start-up
Program parameter 4: Setting the percentage threshold of the upper limit value.
program par.
up
120%
Fig. 46: Adjusting the upper limit
Value range: between 100% and 150%, with simultaneously displaying the absolute limit value.
The maximal settable absolute limit depends on the sensor:
P42, P42A:
P30, P36:
P75:
P75V:
Program parameter 5: Setting the percentage threshold of the lower limit value.
program par.
low: 80%
Fig. 47: Adjusting the lower limit
Value range: between 0% and 99%, with simultaneously displaying the absolute limit value.
Program parameter 6: Zero adjust
The Zer o adj ust pr oc edure mus t be perfor med at c ommissioni ng and after havi ng exchang ed a sens or.
program par.
zero adjust: off
Fig. 48: Status of Zero adjust
For performing a zero adjust press the ENTER key (if no zero adjust is present or for repeating)
Possible choices (only for 4P versions):
separate: All connected sensors must be zero adjusted individually
common: All sensors are zero adjusted at the same time.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
106
Double Sheet Detector R1000 series E20
4
1.35mm
5 mm (.197in.)
3 mm (.118in.)
6.8 mm (.268in.)
9.2 mm (.362in.)
5
0.45mm
Before performing a Zero adjust procedure, verify in any case that
Attention
no sheet is in front of the sensor (the sensors).
6
(each sensor is addressed individually for "on" or "off").
Manual
B0046991 / Rev. 1.6