Roland R1000 Series Manual page 33

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046991 / Rev. 1.6
"CLR parameter (Clear Program Parameter)"
Deletes all program parameters. For doing so, the parameter needs to be set to "yes". Executing
the command requires several minutes, since the program memory will completely cleared. All
program parameters will be reset to the default values and existing teach-in data will be deleted.
Using this function only makes sense if a unit is to be newly used for another machine.
"Password yes/no"
Switches the password request on/off. If the password request is set "on", the system / program
parameters can only be changed after the password has been entered.
"Output level"
Sets the output voltages for outputs 0-,1-,2-sheet. Default setting is 24 VDC.
"External Alignment"
Sets whether an external teach-in / zero adjust is to be possible. If "yes" is set, the PLC can trigger
the procedure via the inputs "Teach-In 0-, 1-sheet". Default setting is "no".
The external alignment may only be performed under supervision of an operator.
"Version"
Indication of the version of the unit.
Factory setting, do not change !
"Number of sensors"
Defines the number of connected sensors. Those sensors are then available for measuring.
"Sensor selection"
Selection of the sensor by program or via the inputs A and B.
"Measuring fast/normal"
For time-critical applications the measuring time can be slightly shortened. If "fast" is selected and
double sheet occurs, the measuring is terminated on reaching the upper switch limit, and the
information "2-sheet" is released. If "normal" is selected, the measuring will be executed to the end
and the measured thickness will be displayed.
"E20-x-x(1)" or E20-4P-x-x(x)
"SW:xx HW:xx"
Identification of unit. Needs to be at hand for telephone support.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33