Mounting
4.2.1

Mounting the MSI18S/E-sensors

Preferably the sensors should be mounted either in sturdy plastic or nonmagnetic stainless steel
brackets.
The transmitter and receiver should be mounted aligned to each other with a sensor gap specified
in the documentation. Sensors should not be mounted flush in the bracket and recessed mounting
should also be avoided in order to prevent accumulation of metallic chips and dirt.
Protruded sensor mounting according to examples "A" or "B" is recommended. Brackets made of
aluminum or other nonferrous metal with high electrical conductivity should be avoided in order to
prevent performance degradation and reduction in sensor gap Ax.
Example A
Example B
Fig. 9: Mounting the MSI18S/E-sensors
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
20
Double Sheet Detector R100 I100
D
>D
D
>D
Manual
for pairs of sensors
Measuring legend:
D: sensor diameter
B: min. 10 mm
Ax: agreed sensor distance, see sensor diagram
B0003308 / 1.4 / 13.02.2013