Data Lists; Machine Data; General Machine Data - Siemens SINUMERIK Series Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

M5: Measurement

7.9 Data lists

Program code
N10 DEF REAL MESSWERT_IN_X[10]
N15 G17 T1 D1
N20 _ANF: G0 X0 F150 ←
N25 MEAS=+1 G1 X100 ←
N30 STOPRE ←
N35 SIGNAL= $AC_MEA[1]
N37 IF SIGNAL == 0 GOTOF_FEHL1
N40 MESSWERT_IN_X[II]=$AA_MW[X]
N50 II=II+1
N60 IF II<10 GOTOB_ANF
N65 M0
N70 M02
N80 _FEHL1: MSG ("Probe not switching")
N90 M0
N95 M02
After the parameter display (user-defined variables) has been selected, the measurement
results can be read in field MEASVALUE_IN_X[10] provided that the program is still being
processed.
7.9
Data lists
7.9.1

Machine data

7.9.1.1

General machine data

Number
Identifier: $MN_
13200
MEAS_PROBE_LOW_ACTIVE
13201
MEAS_PROBE_SOURCE
13210
MEAS_TYPE
13211
MEAS_CENTRAL_SOURCE
532
Comment
; Initial conditions,
: Tool compensation
; preselect for probe
; Prepositioning in the measured axis
; at 1st measurement input when
; switching signal not deflected,
; deflected in the X axis
; Stop decoding for this after
; subsequent evaluation of
; results
; read software switching signal at
; 1. Read measuring input
; Check switching signal
; Read measured value in workpiece
coordinates
; Repeat 10 times
Meaning
Switching characteristics of probe
Measuring pulse simulation via digital output
Type of measurement for PROFIBUS DP drives
Central measuring data source with PROFIBUS DP
drives
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
Extended Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 828d

Table of Contents