Siemens SIPROTEC 7UT613 series Manual page 598

Differential protection
Hide thumbs Also See for SIPROTEC 7UT613 series:
Table of Contents

Advertisement

A Appendix
No.
Description
323.2501
>BLOCK time overcurrent 3I0-3
InRush (>BLK 3I0O/C3Inr)
323.2502
>BLOCK 3I0>> time overcurrent
3 (>BLOCK 3I0-3>>)
323.2503
>BLOCK 3I0> time overcurrent 3
(>BLOCK 3I0-3>)
323.2504
>BLOCK 3I0p time overcurrent 3
(>BLOCK 3I0-3p)
323.2514
Time Overcurrent 3I0-3 3I0>>
BLOCKED (3I0-3>> BLOCKED)
323.2515
Time Overcurrent 3I0-3 3I0>
BLOCKED (3I0-3> BLOCKED)
323.2516
Time Overcurrent 3I0-3 3I0p
BLOCKED (3I0-3p BLOCKED)
323.2521
Time Overcurrent 3I0-3 3I0>>
picked up (O/C 3I0-3>> PU)
323.2522
Time Overcurrent 3I0-3 3I0>
picked up (O/C 3I0-3> PU)
323.2523
Time Overcurrent 3I0-3 3I0p
picked up (O/C 3I0-3p PU)
323.2524
Time O/C 3I0-3 3I0> InRush
picked up (3I0-3>InRush PU)
323.2525
Time O/C 3I0-3 3I0p InRush
picked up (3I0-3p InRushPU)
323.2529
Time Overcurrent 3I0-3 InRush
picked up (3I0-3 InRush PU)
323.2541
Time Overcurrent 3I0-3 3I0>>
Time Out (3I0-3>>Time Out)
323.2542
Time Overcurrent 3I0-3 3I0>
Time Out (3I0-3> Time Out)
323.2543
Time Overcurrent 3I0-3 3I0p
Time Out (3I0-3p Time Out)
323.2551
Time Overcurrent 3I0-3 3I0>>
TRIP (O/C 3I0-3>>TRIP)
323.2552
Time Overcurrent 3I0-3 3I0>
TRIP (O/C 3I0-3> TRIP)
323.2553
Time Overcurrent 3I0-3 3I0p
TRIP (O/C 3I0-3p TRIP)
324.2413
Dynamic settings O/C 3I0-3 are
ACTIVE (3I0-3 Dyn.s.ACT)
325.2404
>BLOCK Earth time overcurrent
2 (>BLK Earth O/C2)
325.2411
Time Overcurrent Earth 2 is OFF
(O/C Earth2 OFF)
325.2412
Time Overcurrent Earth 2 is
BLOCKED (O/C Earth2 BLK)
325.2413
Time Overcurrent Earth 2 is
ACTIVE (O/C Earth2 ACT)
325.2425
Time Overcurrent Earth 2 picked
up (O/C Earth2 PU)
325.2492
O/C Earth2 err.:No auxiliary CT
assigned (O/C E2 ErrCT)
325.2501
>BLOCK time overcurrent Earth
2 InRush (>BLK E O/C2 Inr)
325.2502
>BLOCK IE>> time overcurrent 2
(>BLOCK IE-2>>)
598
Function
3I0 O/C 3
SP
ON
OFF
3I0 O/C 3
SP
*
3I0 O/C 3
SP
*
3I0 O/C 3
SP
*
3I0 O/C 3
OUT
ON
OFF
3I0 O/C 3
OUT
ON
OFF
3I0 O/C 3
OUT
ON
OFF
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
3I0 O/C 3
OUT
*
ColdLoadPickup
OUT
ON
OFF
Earth O/C 2
SP
*
Earth O/C 2
OUT
ON
OFF
Earth O/C 2
OUT
ON
OFF
Earth O/C 2
OUT
ON
OFF
Earth O/C 2
OUT
*
Earth O/C 2
OUT
ON
Earth O/C 2
SP
ON
OFF
Earth O/C 2
SP
*
Log Buffers
Configurable in Matrix
ON
*
LED BI
OFF
*
*
LED BI
*
*
LED BI
*
*
LED BI
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
ON
*
LED
OFF
*
*
LED
*
*
LED
*
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
OFF
*
*
LED BI
*
*
LED
ON
*
LED
OFF
*
*
LED
ON
*
LED
OFF
*
*
LED
ON
*
LED BI
OFF
*
*
LED BI
IEC 60870-5-103
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
7UT613/63x Manual
C53000-G1176-C160-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents