Siemens SIPROTEC 7UT613 series Manual page 592

Differential protection
Hide thumbs Also See for SIPROTEC 7UT613 series:
Table of Contents

Advertisement

A Appendix
No.
Description
205.2404
>BLOCK restricted earth fault
prot. 2 (>BLOCK REF2)
205.2411
Restricted earth fault 2 is
switched OFF (REF2 OFF)
205.2412
Restricted earth fault 2 is
BLOCKED (REF2 BLOCKED)
205.2413
Restricted earth fault 2 is ACTIVE
(REF2 ACTIVE)
205.2421
Restr. earth flt. 2: Time delay
started (REF2 T start)
205.2451
Restr. earth flt. 2: TRIP (REF2
TRIP)
205.2491
REF2 err.: Not available for this
object (REF2 Not avail.)
205.2492
REF2 err.: No starpoint CT (REF2
Err CTstar)
205.2494
REF2 err.: adverse Adaption
factor CT (REF2 Adap.fact.)
205.2631
Restr. earth flt. 2: picked up
(REF2 picked up)
205.2632
REF2: Value D at trip (without
Tdelay) (REF2 D:)
205.2633
REF2: Value S at trip (without
Tdelay) (REF2 S:)
205.2634
REF2: Adaption factor CT M1
(REF2 CT-M1:)
205.2635
REF2: Adaption factor CT M2
(REF2 CT-M2:)
205.2636
REF2: Adaption factor CT M3
(REF2 CT-M3:)
205.2637
REF2: Adaption factor CT M4
(REF2 CT-M4:)
205.2638
REF2: Adaption factor CT M5
(REF2 CT-M5:)
205.2639
REF2: Adaption factor CT starp-
nt. wind. (REF2 CTstar:)
206.2404
>BLOCK Breaker failure 2
(>BLOCK BkrFail2)
206.2411
Breaker failure 2 is switched OFF
(BkrFail2 OFF)
206.2412
Breaker failure 2 is BLOCKED
(BkrFail2 BLOCK)
206.2413
Breaker failure 2 is ACTIVE
(BkrFail2 ACTIVE)
206.2491
Breaker failure 2 Not avail.for this
obj (BkrFail2 Not av)
206.2651
>Breaker failure 2 initiated exter-
nally (>BrkFail2extSRC)
206.2652
Breaker failure 2 (internal)
PICKUP (BkrFail2 int PU)
206.2653
Breaker failure 2 (external)
PICKUP (BkrFail2 ext PU)
206.2654
BF 2 TRIP T1 (local trip) (BF2
T1TRIP(loc))
206.2655
BF 2 TRIP T2 (busbar trip) (BF2
T2TRIP(bus))
592
Function
REF 2
SP
*
REF 2
OUT
ON
OFF
REF 2
OUT
ON
OFF
REF 2
OUT
ON
OFF
REF 2
OUT
*
REF 2
OUT
*
REF 2
OUT
ON
REF 2
OUT
ON
REF 2
OUT
ON
REF 2
OUT
*
REF 2
VI
*
REF 2
VI
*
REF 2
VI
ON
OFF
REF 2
VI
ON
OFF
REF 2
VI
ON
OFF
REF 2
VI
ON
OFF
REF 2
VI
ON
OFF
REF 2
VI
ON
OFF
Breaker Fail. 2
SP
*
Breaker Fail. 2
OUT
ON
OFF
Breaker Fail. 2
OUT
ON
OFF
Breaker Fail. 2
OUT
ON
OFF
Breaker Fail. 2
OUT
ON
Breaker Fail. 2
SP
ON
OFF
Breaker Fail. 2
OUT
*
Breaker Fail. 2
OUT
*
Breaker Fail. 2
OUT
*
Breaker Fail. 2
OUT
*
Log Buffers
Configurable in Matrix
*
*
LED BI
*
*
LED
ON
*
LED
OFF
*
*
LED
ON
m
LED
OFF
ON
m
LED
*
*
LED
*
*
LED
*
*
LED
ON
*
LED
OFF
ON
OFF
ON
OFF
*
*
LED BI
*
*
LED
ON
*
LED
OFF
*
*
LED
*
*
LED
*
*
LED BI
ON
*
LED
OFF
ON
*
LED
OFF
ON
m
LED
ON
m
LED
IEC 60870-5-103
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
7UT613/63x Manual
C53000-G1176-C160-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents