Individual settings

4.4 Setting the sewing foot

4.4.1 Setting the lift stroke

When the pedal is pressed to position -1, the sewing feet can be raised
during sewing, e. g. to move the sewing material (
Proper setting
The distance between the raised sewing feet and the throat plate is preset
to 9 mm on delivery.
Cover
• Disassembling the head cover ( p. 16)
Fig. 22: Setting the lift stroke
(1) - Screw
To set the lifting height of the sewing foot:
1. Loosen the screw (1).
2. Adjust the height of the stop (2).
3. Tighten the screw (1).
Service Instructions 610-10/630-10 - 01.0 - 12/2016
Operating Instructions).
(2) - Stop
37