Individual settings

4.15.2 Setting the stroke movement timing

Fig. 59: Setting the stroke movement timing
(1) - Stroke eccentic
(2) - Screw
Proper setting
At handwheel position F, the 1
direction of rotation is aligned with the slot (3) of the push rod.
Disturbance
• Increased wear of mechanical parts
• Feed behavior not optimal, possibly loud machine noises
Cover
• Disassembling the arm cover ( p. 17)
To time the stroke movement:
1. Lock the machine in place at position F ( p. 27).
2. Loosen both screws of the stroke eccentric (1).
3. Turn the stroke eccentric (1) until the 1
4. Tighten both screws of the stroke eccentric (1).
5. Remove the lock ( p. 27).
Service Instructions 610-10/630-10 - 01.0 - 12/2016
tion is aligned with the slot (3) of the push rod.
(3) - Slot
st
screw (2) in the stroke eccentric's (1)
st
screw in the direction of rota-
71