Setting The Looper Drive Housing - DURKOPP ADLER 610-10 Service Instructions Manual

Hide thumbs Also See for 610-10:
Table of Contents

Advertisement

Individual settings

4.5.6 Setting the looper drive housing

Fig. 30: Setting the looper drive housing (1)
(1) - Gage
(2) - Looper shaft
(3) - Looper shaft lower edge
Proper setting
The needle tip should point to the center of the looper shaft (2), and the
looper shaft lower edge should be parallel to the underside of the throat
plate.
This corresponds to a distance of 50.5 mm between the lower edge of the
looper shaft (3) and the throat plate support (5).
Disturbance
• Damage to the looper
• Damage to the needle
• Damage to the thread cutter blade
• Missing stitches
• Thread breakage
Order
• Removing the needle
• Removing the throat plate ( p. 20)
• Disassembling the oil pan ( p. 15)
• Disassembling the thread cutter ( p. 21)
• Disassembling the needle guard ( p. 23)
• Removing the looper mounting ( p. 24)
Service Instructions 610-10/630-10 - 01.0 - 12/2016
(4) - Clamping screw
(5) - Throat plate support
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

630-10

Table of Contents