Setting The Stop Positions Parameters; Setting The Sewing Foot Lift Parameters - DURKOPP ADLER D867 M-Type Delta Service Instructions Manual

Hide thumbs Also See for D867 M-Type Delta:
Table of Contents

Advertisement

Programming

19.4.4 Setting the Stop Positions parameters

Various settings can be made for the stop positions. The possibilities are
explained in more detail in the table.
Icon

19.4.5 Setting the Sewing foot lift parameters

Various settings can be made for the sewing foot. The possibilities are
explained in more detail in the table.
Icon
Service Instructions M-TYPE DELTA - 00.0 - 12/2019
Menu items
Lower needle position
Holding position of the needle in the
material.
Threading position
Position for the proper function of the
threader, e.g. with thread lever at top dead
center.
Needle up position
Holding position of the needle outside of
the material.
Needle position after turn back
Stop position after thread cutting (reversal
position).
Menu items
Max. sewing foot lifting height • Value range with
Step motor speed
Speed at which the sewing feet will be
lifted.
Value range
• Value range
000 - 359
• Value range
000 - 359
• Value range
000 - 359
• Value range
000 - 359
Value range
standard FA
01.0 – 20.0 [mm]
• Value range with KFA
01.0 – 18.0 [mm]
• Value range
01 - 60
131

Advertisement

Table of Contents
loading

Table of Contents