Maintenance
6.3.2 Draining the water condensation
Water condensation will accumulate in the water separator (2) of the com-
pressed air maintenance unit.
Proper setting
Water condensation must not rise up to the level of the filter element (1).
Check the water level in the water separator (2) on a daily basis.
Fig. 97: Draining the water condensation
(1) - Filter element
(2) - Water separator
To drain water condensation:
1. Disconnect the machine from the compressed air supply.
2. Place the collection tray under the drain screw (3).
3. Loosen the drain screw (3) completely.
4. Allow water to drain into the collection tray.
5. Tighten the drain screw (3).
6. Connect the machine to the compressed air supply.
Service Instructions 610-10/630-10 - 01.0 - 12/2016
NOTICE
Property damage from excess water condensation!
Too much water condensation can result in damage to the machine.
If necessary, drain the condensation water as described.
①
②
(3) - Drain screw
③
115