Traffic provisioning
Remote SHDSL Power Supply (RPS) Support
The 1643 AM/AMS manages an external Remote SHDSL Power Supply (RPS) box via
the MDI/MDO interfaces. Note that remote power supply must be set to 'managed
mode' by the DIP switch=ON in the power box.
The 1643 AM management system can also be set to 'managed mode' for the remote
power supply.
The 1643 AM/AMS supports the following remote power supply provisioning
functions.
Restart_cmd
• Enable/Disable RPS related alarms (per port and not per alarm). This provisioning
is used to suppress alarms generated by the RPS module.
The 1643 AM/AMS remote power supply module supports the following alarms.
• RPS power failure (per box)
• Overl: Overload (per port)
• OpenC: Open circuit (per port)
• FSD: Forced shut down (per port)
• Leak: Leakage asymmetrical (per port)
• HVolt: Overvoltage alarm (per port)
Note that the MDI interfaces 1...4 and MDO interfaces 1...4 will not function as
normal when the RPS is set to managed mode.
....................................................................................................................................................................................................................................
8-16
: Restarts the RPS module after forced shutdown