Optional Fan / Blower Replacement
The Optional Fans or Blowers supplied with your fan kit are the best
quality available. These Fans should provide many years of trouble
free service. There are 2 blowers for this appliance, one which has the
motor on the right side and the other on the left side.
** If the fireplace is installed, the Gas Supply may need to be disconnected
from the Appliance. If this is the case, a licensed gas fitter will need
to provide this service. Images of RFKFID High Output Fan Kit shown.
Installation instructions are the same for RFKFIDECO Economy Fan Kit.**
1). If installed, disconnect Electrical Power. Always disconnect the
power when servicing any appliance.
2). Remove Front and Rear Faceplate. See the section on Faceplate
installation for details.
3). Remove the Flue Collar Slide Plate. See the section on Vent
Connection for details.
4). Remove the Fireplace from the cavity.
5). Remove all screws necessary to remove the Outer Shell Back.
40
Figure 10.1
Figure 10.2
6). Cut the Zip Strap holding the Fan Wire Harness.
7). Cut the Zip Strap that
holds the Fan Wire
Harness in the Valve
Compartment.
Figure 10.4
Operation
Figure 10.3
8). Disconnect the Fan Wire
Harness.
Figure 10.5