Montigo 30FIDNIL-01 Installation & Maintenance Manual page 15

I series inserts indoor gas fireplace
Hide thumbs Also See for 30FIDNIL-01:
Table of Contents

Advertisement

Gas line connection
The Insert is supplied with a flexible gas line that uses a ½" female flare
to connect to your service. The flexible gas line is a one time connection.
If you ever have to break the connection, you must replace the flexible
gas line. There is also a safety shutoff valve that is built in and operated
when needed used the door removal tool. Depending on your local
gas codes, you may need to provide an additional gas shut off valve
or even hard pipe the unit. In the event that you need to hard pipe the
gas supply, a union will be required.
Emergency Shut-off Valve
This appliance is equipped with a shut-off valve for use in case of
emergency. It is located on top of the appliance gas valve and can be
accessed and operated through the front of the fireplace using the
door tool. The appliance is shipped from the manufacturer with the
emergency shut-off valve in the closed position.
Hook the door tool into the arm of the emergency shut-off valve. Pull
the door tool towards you to open the valve and push it away from
you to close the valve.
PULL THIS
DIRECTION TO OPEN
XG0528 - 170223
Figure 5.0
Figure 5.1
HOOK DOOR
TOOL HERE
Figure 5.2
Fuel Supply + Manifold Pressure
Checking
It's imperative that you verify that the supply pressure to your appliance
is adequate and that the valve is supplying the correct pressure to the
pilot and main burner. The pilot burner operates at line pressure and
may need further adjustment. The valve outlet pressure is set by the
manufacturer of the valve but should be verified upon install. Follow
the following steps to perform this system check. Inlet pressure must
be checked with fireplace burning.
1. Remove the 2 screws from the Valve Mounting Bracket so that
the valve can be swung away from the unit. The Shut off lever
needs to be in the "off" position to be able to swing the valve out
of the valve control box.
2. Using a slotted screw driver, loosen the Manifold Tap on the
valve front.
Figure 5.3
3. Attach a silicone hose to over top of the pressure tap on the
valve face. Connect the hose to a manometer.
Installation
Figure 5.4
Figure 5.5