Control Board Replacement; Control Board Fuse Replacement - Montigo 30FIDNIL-01 Installation & Maintenance Manual

I series inserts indoor gas fireplace
Hide thumbs Also See for 30FIDNIL-01:
Table of Contents

Advertisement

Control Board Replacement

1. Disconnect the appliance from the main power and shut off any
gas supply prior to performing any maintenance.
2. Remove the Front Faceplate. See the appropriate section for
instruction on Faceplate removal.
3. Carefully cut the zip strap
that secures some of the
wires from the top of the
Control Board.
Figure 11.0
5. Remove the screws that
fasten the board to the
Mounting Bracket.
Figure 11.2
7. Stick the little Zip Strap
and Retaining Pad to the
top of the Control Board.
Figure 11.4
XG0523 - 170223
4. Unplug all of the electrical
connections on the left
and right side of the board.
Figure 11.1
6. Remove and replace the
board with the new unit.
Figure 11.3
8. Using the Zip Strap, secure
all the wires neatly into
the Control Box Area. Re-
connect the Electrical and
Gas supply.
Figure 11.5

Control Board Fuse Replacement

1. Disconnect the appliance from the main power and shut off any
gas supply prior to performing any maintenance.
2. Remove the Front Faceplate. See the appropriate section for
instruction on Faceplate removal.
3. The Fuse is in a plastic retainer, located on the right side of the
Control Board. The Plastic Retainer plugs into the Control Board
as a Cable End would. You may have to gently use a screw driver
to wiggle this away from the Control Board.
4. Remove and replace the Fuse from the Plastic Retainer.
4. Re-install the Plastic Retainer into the Control Board.
5. Re-install the Front Faceplate.
6. Re-connect Electrical and Gas supply to the appliance.
Operation
Figure 11.6
Figure 11.7
Figure 11.8
45