Installing Fan Kit; Wiring For The Optional Fan Kit - Montigo L38DF Installation & Maintenance Manual

L-series residential fireplace
Table of Contents

Advertisement

Installing the remote On/Off Wall Switch
The L38DF* gas valve may be connected to a wall switch. Do nOT
connect any external power to the remote switch. The valve will
generate its own power on a millivolt circuit or will draw its power from
an AC Connection inside the fireplace, depending on the model of the
unit. Use only low voltage wire, and DO nOT connect any external
power to the remote switch.
Refer to Figure 18 or 19 for wiring requirements.
nOTE: The switch location must not exceed 30' from the fireplace.

Wiring for the optional Fan Kit

All L38DF* fireplaces may be equipped with optional fan kits for
circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code Part
1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included with
the fan kit.
5/1/60 Supply
G
L1 L2
Quick Connect
Figure 20. Wiring schematic for optional fans.
nOTE: If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
XG0180 - 053111.1
Installation
L2-WH
G
L1-BLK
p g
lu to motor
L38DF* Indoor Gas Fireplace